UNIcon
CPG-..AVC
Sensor-control module for differential
pressure and volume ow
Operating Instructions
Keep for reference!
Software version: from Version 1.00
L-BAL-E286-GB 1904 Index 004
Part.-No.
english
Question and Answer IconNeed help?

Do you have a question about the ZIEHL-ABEGG UNIcon CPG-6000AVC and is the answer not in the manual?

ZIEHL-ABEGG UNIcon CPG-6000AVC Specifications

General IconGeneral
Housing materialPlastic
Connection typeScrew terminals
Ambient temperature-20 °C to +50 °C
Storage temperature+70 °C
Relative humidity5 % to 95 %, non-condensing
ProtocolModbus RTU

Summary

2 Safety instructions

2.1 Safety Precautions

Emphasizes critical safety precautions for installation, operation, and maintenance by qualified personnel.

2.2 Intended Use

Defines the device's purpose for measured value acquisition of differential pressures with non-aggressive gases.

4 Mounting

5 Electrical installation

5.1 EMC-compatible installation of control lines

Advises maintaining distance from powerlines and motor wires to prevent interference and proper shield connection.

5.2 Connection Voltage supply

Details the connection for supply voltage at '+Us' and 'GND' terminals, emphasizing PELV sources.

5.3 Output voltage 0...10 V

Explains the connection for the 0...10 V output signal to terminals 'A' and 'GND' and parallel control of multiple devices.

5.6 RS-485 interface for MODBUS

Explains the RS-485 interface connection for networking via MODBUS, specifying terminals A, B, and GND.

5.6.1 Automatic addressing

Describes the process of automatic addressing for MODBUS networks using ID1 and ID2 connections.

7 Modes/Start-up

7.1 Select operation mode

Explains how to select pre-programmed operating modes (e.g., 4.00, 4.01) to define the device's basic function.

7.2 Start-up

Outlines the procedure for device start-up, including mounting, connection checks, and setting parameters.

8 Programming

8.1 Pressure sensor 4.00 and pressure control 4.01 + 4.02

Covers programming for pressure sensor and control functions, including base setup and operation settings.

8.1.2 Settings for operation 4.01 + 4.02

Details specific operational settings for pressure control modes, such as setpoint, Pband, and output voltage.

8.2 Volume sensor 5.00 and volume control 5.01 + 5.02

Covers programming for volume sensor and control functions, including base setup and conversion factors.

8.2.3 Setting for operation 5.01 and 5.02

Details specific operational settings for volume flow control modes, including setpoint, Pband, and output voltage.

8.7 MODBUS SLAVE

Introduces the MODBUS SLAVE interface for networking with master building control systems using the MODBUS-RTU protocol.

8.7.2 MODBUS Register

Explains the MODBUS register map, detailing holding registers for device configuration and control.

Related product manuals