ZIROX XS22 - User Manual

Default Icon
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ZIROX Sensoren & Elektronik GmbH
Am Koppelberg 21, D-17489 Greifswald +49 (0) 3834 8309-00, Fax: -29 E-mail: info@zirox.de
ZIROX Oxygen Measuring Technology
Measuring System
Vacuum probe XS22
Electronic unit E2010
for oxygen measurements in vacuum applications
Manual
Operating voltage: 24 V DC
Question and Answer IconNeed help?

Do you have a question about the ZIROX XS22 and is the answer not in the manual?

Summary

Introduction to ZIROX Oxygen Measuring System

How to Use This Manual

Guide on manual usage, manufacturer details, and document structure.

Copyright and Usage Restrictions

Outlines copyright protection and usage restrictions for the manual content.

Commonly Used Symbols for Safety

Explains symbols for imminent and indirect danger to ensure user safety.

Safety Instructions for Operation

Provides essential safety guidelines for operating the oxygen measuring system.

Application of the Measuring System

Details the primary uses and typical examples for the oxygen measuring system.

Overview of the Measuring System

Technical Data for ZIROX System

Technical Specifications of Probe XS22

Lists technical specifications for the ZIROX XS22 oxygen probe.

Technical Specifications of Evaluation Electronics E2010

Details technical specifications for the ZIROX E2010 evaluation electronics unit.

Composition and Operation of E2010 Unit

Front Panel Layout and Keys

Describes the front panel layout, including the display and control keys.

Rear Panel Connections

Details the rear panel connections for probe, power supply, and output signals.

Installation and Initiation Procedures

General Installation Guidelines

Instructions for connecting the sensor or probe to the device.

Reference Air Supply for ZIROX Probes

Explains the requirement and procedure for reference air supply for specific probes.

Probe Mounting Instructions

Information on how to mount the ZIROX probes, including flange types.

Waiting for Operating State

Describes the waiting period required for the system to reach its operating state.

Parametrization of the Measuring System

Menu Operation Example

Illustrates the process of menu operation and parameter display.

System Display Information

Shows examples of different display screens during system operation.

Adjustable Parameters

Lists and explains parameters that can be adjusted in the SETTINGS menu.

Zero Calibration Procedure

Details the procedure for performing a zero point calibration in clean air.

Span Gas Calibration Procedure

Outlines the steps for conducting a span gas calibration for the sensor.

Resetting Calibration Values

Explains how to reset calibration values back to default settings.

Error Messages During Calibration

Lists common error messages that may occur during the calibration process.

Calibration Menu Navigation Diagram

Provides a schematic diagram illustrating the calibration menu flow.

Status Display and Error Messages

Potential Fault Causes and Clearance

Details for Use of ZrO2-probes in Vacuum Technology

Theoretical Relations and Nernst Equation

Explains the theoretical principles and the NERNST equation for potentiometric probes.

Instructions for Vacuum Calibration

Provides practical guidance and instructions for calibrating the probe in vacuum applications.

Warranty Information

Declaration of Conformity

ZIROX XS22 Specifications

General IconGeneral
BrandZIROX
ModelXS22
CategoryMeasuring Instruments
LanguageEnglish