158
Press the OK key.
The Advanced Options menu will appear;
Adv Option ▲
▼
Clear Admin Pri
Show Score N
► Match Thr 45
Scroll with the ▲/▼ keys and place the cursor ( ) alongside Match Thr.
Press the OK key.
Notice the 45 in Match Thr becomes highlighted;
Adv Option ▲
▼
Clear Admin Pri
Show Score N
►Match Thr 45
Use the keypad or scroll ▲/▼ keys to change the threshold setting.
Lessening the threshold lessens the sensitivity of the sensor when reading
“difficult” fingerprints.
If the F707/708 is having difficulty reading most users’ fingerprints, then
consider lessening the threshold in 5-unit increments until the vast
majority of users’ fingerprints can be read consistently.