Important warnings covering installation, grounding, wire types, and component handling for user and equipment safety.
Description of the POWER (red) and RUN (green) indicators for normal system operation.
Details on valve regulated lead-acid battery, including charge voltage, standby use, capacity, and handling cautions.
Illustrates mounting points like heat dissipation and thread holes, and shows wiring for control panel, charging circuit, and battery.
Explanation of various LED indicators on the control panel, including LINK, ACT, TX, RX, Aux Output, Lock, POWER, RUN, and CARD.
Guidance on recommended wire types and conductors for power cords and communication interfaces like Wiegand readers.
Details on SD Card, Ethernet, RS485 interfaces, auxiliary inputs/outputs, lock power, device power, door buttons, and Wiegand readers.
Instructions for setting RS485 addresses via DIP switch and restoring factory default settings.
Guidance on using DIP switch position 8 to set the terminal resistance for RS485 communication.
Explains how to connect NO (Normally Open) and NC (Normally Closed) locks to the control panel.
Details on setting dry/wet modes for locks and the necessity of a parallel FR107 diode for protection.
Instructions for setting up communication between the PC and control panels using TCP/IP protocol.
Guidelines for RS485 communication, including wire types, bus length limits, and stability considerations.
Important warnings covering installation, grounding, wire types, and component handling for user and equipment safety.
Description of the POWER (red) and RUN (green) indicators for normal system operation.
Details on valve regulated lead-acid battery, including charge voltage, standby use, capacity, and handling cautions.
Illustrates mounting points like heat dissipation and thread holes, and shows wiring for control panel, charging circuit, and battery.
Explanation of various LED indicators on the control panel, including LINK, ACT, TX, RX, Aux Output, Lock, POWER, RUN, and CARD.
Guidance on recommended wire types and conductors for power cords and communication interfaces like Wiegand readers.
Details on SD Card, Ethernet, RS485 interfaces, auxiliary inputs/outputs, lock power, device power, door buttons, and Wiegand readers.
Instructions for setting RS485 addresses via DIP switch and restoring factory default settings.
Guidance on using DIP switch position 8 to set the terminal resistance for RS485 communication.
Explains how to connect NO (Normally Open) and NC (Normally Closed) locks to the control panel.
Details on setting dry/wet modes for locks and the necessity of a parallel FR107 diode for protection.
Instructions for setting up communication between the PC and control panels using TCP/IP protocol.
Guidelines for RS485 communication, including wire types, bus length limits, and stability considerations.
| Type | Basic access control reader |
|---|---|
| Interface | RJ-45 / RS-485 |
| Case design | Bare |
| Product color | Black |
| Alarm function | Yes |
| Number of users | 30000 user(s) |
| Fingerprint reader | No |
| Authentication type | Access chip/card, Biometric, Password |
| Maximum number of doors | 2 door(s) |
| RS-485 ports | 1 |
| PC connection | RS-485/RJ-45 |
| DC current (max) | 2 A |
| Switchable current | 1.5 A |
| Operating temperature (T-T) | 0 - 40 °C |
| Operating relative humidity (H-H) | 20 - 80 % |
| Depth | 106 mm |
|---|---|
| Width | 160 mm |
| Weight | 3400 g |