If
the
Power
Cord
is
detached:
•Reinsert
the
Power
Cord
if it
is
accidentally
detached.
•It
the
cord
is
detached
for
more
than
a
few
minutes
and
reinserted,
the
product
returns
to
the
195°F
Keep
Warm
mode
and
may
start
reboiling
automatically.
■
Temperature
Conversion Guide
Fahrenheit
(°F)
Celsius
(°C)
212 100
208
98
207 97
205
96
195
90
190
88
185
85
178
81
175
80
169 76
167
75
160
70
73
23
For
preparing
baby
formula
160°F
Keep
Warm
Mode
160°F
is
ideal
for
preparing
baby
formula.
Select
the
"160"
on
the
Display.
When the boiling
process has
completed, a melody
sounds, the BOIL
light turns off,
and
the KEEP WARM
light begins
to
blink.
(
)
If
initiated
during
Keep
Warm
mode,
the
light
will
blink
2
seconds
after
the
selection.
e1t
you
wish
to
shorten
the
time,
add
less
water
to
the
Inner
Container.
4i•11w1111•
·
Put
in
to
1.0
of
an
amount
of
water
Water
Level
Gaug
•
Once
the
water
temperature
reaches
about
160°F
"160"
appears
on
the
Display
and
the
KEEP
WARM
light
stops
blinking
and
remains
on
.
■
Length
of time for the water temperature
to
reach
160°F
after boiling:
1.0
L
Max
Capacity
-----------
CV-DCC40
Approx
. 2
hours
and
30
minutes
Approx.
6
hours
and
30
minutes
CV-DCC50
Approx.
1
hour
and
50
minutes
Approx.
4
hours
and
50
minutes
(At
a
room
temperature
of
73°F.)
•The
length
of
time
for
the
water temperature
to
reach
160°F
will
vary
depending
on
the
amount
of water
and
room
temperature.
When preparing baby formula:
160°F
is
ideal
for
preparing
formula
.
Dissolve
the
formula
and
let
cool
to
optimum
temperature
(slightly
higher
than
body
temperature).
If
fed
without
cooling,
babies
are
at
risk
of
scalding.
·
Be
sure
to
check
that
the
Keep
Warm
light
is
on
and
NOT
blinking
before
dispensing.
·
Do
not
use
the
Quick
Temp
mode
.
(see
pg.14)
For
saving
electricity
Vacuum Insulation Keep
Warm Mode
This
mode
saves
electricity
by
shutting
off
the
power
to
the
heater
after
the
boiling
process
is
completed
and
keeps
it
warm
by
thermal
insulation.
Select
"VACUUM"
on
the
Display.
Turns
off
-~-o
UICKTEMP
f)i_~
~
~ ; (
I(
\_g!,)
175
160~_,
•:
'--
When the boiling process has completed, a
melody sounds,
and
the BOIL light turns off.
■
Water
temperature during VACUUM
INSULATION Keep Warm Mode:
After
boiling
completes
2
hours
later
4
hours
later
6
hours
later
CV-DCC40
Approx
.
190°F
Approx
.
178°F
Approx
.
167°F
CV-DCC50
Approx
.
185°F
Approx
.
169°F
Approx
.
160°F
(Temperatures
are
measured
in
the
center
of
the
Inner
Container
and
are
based
on
a
room
temperature
of
73°F,
with
the
maximum
amount
of
water.)
•Temperature
is
measured
in
the
center
of
the
Inner
Container
.
The
water
temperature
in
the
upper
and
lower
area
will
differ
as
time
pass,
and
the
temperature
in
the
center
is
measured
as
the
average
.
•As
the
water
temperature
drops,
the
display
temperature
may
be
lower
than
actual
when
the
Vacuum
Insulation
Keep
Warm
mode
is
selected
.
•The
lower
the
amount
of
water,
the
faster
the
temperature
will
drop.
•During
the
Vacuum
Insulation
Keep
Warm
mode,
the
product
will
not
automatically
start
reboiling
.
To
resume
boiling,
manually
press
the
REBOIUQUICK
TEMP
button.
13