Zonex DigiTract 4 - STATUS LED LEGEND

Zonex DigiTract 4
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
SYSTEM CONTROLLER - HEAT PUMP
STATUS LEDs
O/B Y1 Y2 G W2 PWR DPR MODE FUNCTION
OFF OFF OFF OFF OFF OFF
OFF
Off Power off
OFF OFF OFF OFF OFF ON OFF On
Power on, blower off, zones satisfied
ON/OFF OFF OFF ON
OFF
ON
0 Vent Blower on, compressor(s) off, all zone dampers open
ON/OFF OFF OFF OFF OFF
ON
1 Purge
Blower off, compressor(s) off, Dampers with LEDs on are closed
A
ON
OFF
ON
OFF
ON
1 Y1 Cool
1st stage cool, blower on. Dampers with LEDs on are closed
A
ON
ON
ON
OFF
ON
1 Y2 Cool
2st stage cool, blower on. Dampers with LEDs on are closed
B
ON
OFF
ON
OFF
ON
1
Y1 Cool
1st stage cool, blower on. Dampers with LEDs on are closed
B
ON
ON
ON
OFF
ON
1
Y2 Cool
2st stage cool, blower on. Dampers with LEDs on are closed
ON/OFF OFF OFF
ON
ON
ON
0
Em. Heat
Auxiliary and emergency heat on
OFF OFF OFF
ON
OFF
FL
1 Cap Cut out
Blower on, all compressors off. Dampers with LED on are closed
ON/OFF
ON
ON
ON
ON
ON
1
Em. Heat
If below 90°, stages up to Y1, Y2 and W2
ON/OFF OFF OFF
ON
ON
ON
1
Em. Heat
Fossil Fuel mode, stages uo to W2 only
STATUS LED LEGEND
FL = Flashing A = On when reversing valve jumper is in O position B = On when reversing jumper is in B position
C = On when auxiliary heat is energized 1= One or more damper LEDs on 0 = All damper LEDS are off