Why does my Zonex Control Systems blower run continually?
- JJessica RuizAug 12, 2025
The controller might be in cool mode. To resolve this, initiate a thermostat call.
Why does my Zonex Control Systems blower run continually?
The controller might be in cool mode. To resolve this, initiate a thermostat call.
What to do if all Zonex Control Systems thermostats will not call?
A possible cause is a loss of 24V AC on R and C. You should repair the power source.
Why won't my Zonex DigiTract 4 initiate cooling cycle?
This issue may arise if the controller is in heat mode, in which case there will be a delay prior to changeover. Also, the controller may be in changeover from heat mode, and the 4-minute purge cycle must complete before cooling starts.
What to do if Zonex Control Systems zone dampers will not close?
The dampers might be incorrectly wired. To solve this, correct the damper wiring.
What to do if my Zonex Control Systems heating calls short cycle?
This can occur if the heating anticipator is incorrectly set; set the anticipator to the lowest setting. Also, the bypass damper might be opening prematurely; adjust the bypass damper closed with all zone dampers open.
What to do if Zonex DigiTract 4 cooling calls short cycle?
If the LAT is shorted (0V dc on + and – with LAT installed), replace the LAT. Alternatively, the LAT wiring might be shorted (0V dc on + and – with LAT installed); in this case, repair the LAT wiring.
What to do if my Zonex DigiTract 4 Control Systems zone damper remains closed?
The transformer VA may be too low. Replace it with a transformer that has the correct rating.
What to do if Zonex Control Systems triac shorted?
Replace the controller, and check 24 V AC.
Details the operational modes and sequences for gas/electric systems.
Lists and explains the terminals and features of the controller.
Explains operational modes for heat pump systems.
Lists and explains the terminals for the heat pump controller.
Explains the meaning of the status LEDs on the controller.
How the system manages cooling based on LAT.
Staging and control for gas/electric heating.
Staging and control for heat pump heating.
Instructions for installing the LAT sensor.
Instructions for installing the OAS sensor.
Describes low and medium pressure round dampers.
Details medium pressure round dampers.
Details sizes and typical capacities for round dampers.
Introduces rectangular damper types.
Details low pressure rectangular dampers.
Details medium pressure rectangular dampers.
Details heavy duty rectangular dampers.
Provides dimensions for low/medium rectangular dampers.
Provides dimensions for heavy duty rectangular dampers.
Guidance on sizing zone dampers.
Important notes for installing zone dampers.
Introduces barometric bypass dampers.
Instructions for installing barometric bypass dampers.
Procedures for setting up barometric bypass dampers.
Testing the barometric bypass damper functionality.
Guidance on sizing electronic bypass dampers.
How to select round electronic bypass dampers.
How to select rectangular electronic bypass dampers.
Table for selecting rectangular electronic bypass dampers.
How to connect multiple bypass dampers to one sensor.
Explains bypass dampers with integrated static pressure control.
Details the integrated pressure control system.
Instructions for installing the bypass damper.
Procedures for setting up the bypass damper control.
How to test the static pressure controller.
Guidance on selecting transformers and fuses for dampers.
Procedure for testing the system in gas/electric mode.
Procedure for testing the system in heat pump mode.
Common issues and corrective actions for the system.
Chart relating LAT sensor voltage to temperature.