ZXCLOUDR5300G3MaintenanceGuide
3.8TroubleshootingHardDisks
Runtheappropriatediagnostictest.Dependingontheresultsofthediagnosticstest,
performthefollowingsteps:
1.Restartthesystem,andpressF10duringsystemstartuptoruntheLifecycle
Controller,andthenruntheHardwareCongurationwizardtochecktheRAID
conguration.
2.EnsurethattheharddriveshavebeenconguredcorrectlyfortheRAIDarray.Ifa
harddriveintheRAIDisfaulty,keeptheharddriveofineandresetthedrive.
3.Exitthecongurationutilityandallowthesystemtoboottotheoperatingsystem.
4.Ensurethattherequireddevicedriversareinstalledandconguredcorrectly.
5.VerifythatthecontrollerisenabledandthedrivesaredisplayedintheSystemSetup.
3.9TroubleshootingExpansionCards
Runtheappropriatediagnostictest.Dependingontheresultsofthediagnosticstest,
performthefollowingsteps:
1.Turnoffthesystemanditsperipherals,anddisconnectthesystemfromthepower
source.
2.Openthecabinetcoverplate.
3.Ensurethateachexpansioncardisrmlyinstalledinitsconnector.
4.Closethecabinetcoverplate,andpoweronthesystem.
5.Ifthefaultpersists,openthecabinetcoverplate,removeallexpansioncards,and
theninstallthemagain.
6.Closethecabinetcoverplate.