EasyManua.ls Logo

ZURN Aquaflush Z6001 User Manual

ZURN Aquaflush Z6001
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Zurn Industries, LLC
511 W. Freshwater Way, Milwaukee, WI U.S.A. 53204 · Ph. 1-855-ONE-ZURN, Fax 919-775-3541
In Canada
| Zurn Industries Limited
7900 Goreway Drive Unit 10, Brampton, Ontario L6T5W6 · Ph. 905-405-8272, Fax 905-405-1292
www.zurn.com
Rev. A
Date: 7/25/2018
C.N. No. SAN008311
Prod. | Dwg. No. FV250
Z6003
Z6000
Aqua ush
®
Z6000 Series
Aqua ush Exposed Flushometer
Installation, Operation, Maintenance
and Parts Manual
Patented and Patents Pending
LIMITED WARRANTY
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative nishes warranted for one year. We will replace at no costs goods that prove defective provided we are
noti ed in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the
defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the
purchaser assume all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability
is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a
period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and listed
are approximate and are not guaranteed.
WARNING: Cancer and Reproduc ve Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproduc vo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et e ets néfastes sur la reproduc on - www.P65Warnings.ca.gov
Aqua ush Exposed
Closet/Urinal Systems
Z6000
Z6001
Z6003
Z6010
Z6014
Z6017
Z6096
Z6099
NOTE: The information in this manual is subject to change at any time without notice. Installations may
be performed at different times of construction by different individuals. For this reason, these instructions
should be left on-site with the facility or maintenance manager.
NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.
Question and Answer IconNeed help?

Do you have a question about the ZURN Aquaflush Z6001 and is the answer not in the manual?

ZURN Aquaflush Z6001 Specifications

General IconGeneral
ApplicationCommercial
Fixture TypeWater Closet
Flush TypeManual
Valve TypeDiaphragm
Operating Pressure15 - 100 psi
Water Consumption1.6 GPF
Flush Valve TypePiston
MaterialBrass
Inlet1" IPS

Summary

Aquaflush Exposed Systems Overview

Product Identification and Warnings

Lists available Aquaflush Exposed models and highlights critical safety warnings, including those for cancer and reproductive harm.

Limited Warranty Information

Product Specifications and Options

Engineering Details

Technical specifications of the ZURN Aquaflush Exposed Flush Valve, including material and feature descriptions.

Model and Flow Rate Configurations

Details on different ZURN Aquaflush models and their associated flow rates (e.g., HET, WS1, ULF) for various fixtures.

Sweat Solder Adapter Installation

Installation Prerequisites

Essential pre-installation steps and important notes for installing the sweat solder adapter, emphasizing code compliance and protection of finishes.

Step-by-Step Installation Guide

Visual and textual instructions for the correct installation procedure of the sweat solder adapter onto the water supply pipe.

Flush Valve Installation Procedures

Stop Valve and Tailpiece Assembly

Instructions on assembling the stop valve, tailpiece, and ensuring proper O-ring seal before connecting to the flush valve.

Vacuum Breaker and Spud Nut Connection

Guidance on determining vacuum breaker tube length and connecting the vacuum breaker tube assembly and spud nut to the fixture.

System Setup and Flushing

Supply Piping Flushing Procedure

Detailed steps for flushing the supply piping to remove debris before final valve operation, ensuring system cleanliness.

Fine-Tuning Flush Volume

Procedure for adjusting the control stop to achieve optimal flush volume and evacuation for the installed fixture.

Repair and Replacement Parts

Component Identification

Visual guide with numbered parts identifying components of the Aquaflush Exposed Flushometer for repair or replacement.

Repair Kit and Parts Catalog

Listing of all available repair kits and individual parts, categorized by function (covers, stops, handles, etc.) for easy ordering.

Troubleshooting and Maintenance

Common Operational Issues and Solutions

A guide to diagnosing and resolving typical problems encountered with the flush valve's operation, including causes and corrective actions.

Care and Seasonal Preparation

Best practices for maintaining the chrome finish and preparing the valve for seasonal shutdowns to prevent damage.

Related product manuals