Chapter 3 Troubleshooting
VOP1372G-61 User’s Guide
29
9 This is an example Xmodem configuration upload using HyperTerminal. Click Transfer, then Send
File to display the following screen.
Figure 14 Example Xmodem Upload
10 After a successful firmware upload, the line card restarts. The console port speed automatically
changes back to 9600 bps when the line card restarts.
Type the firmware file's
location, or click Browse to
search for it.
Choose the 1K Xmodem
protocol.
Then click Send.
Bootbase Version: V1.00 | 03/23/2007 16:10:06
FLASH: AMD 32M
Hardware Version:
Serial Number:
RAM: Size = 133120 Kbytes
ZyNOS Version: V3.97(UHE.0) | 05/19/2011 11:56:26
Press any key to enter debug mode within 3 seconds.
...........
Enter Debug Mode
atba5
Now, console speed will be changed to 115200 bps
OK
atur
Starting XMODEM upload (CRC mode)....
CCCCCCCC
Total 2003968 bytes received.
Erasing...............................
...........................................................................
...........................................................................
...........................................................................
...........................................................................
...........................................................................
...........................................................................
.........
OK
System Reboot...
Console speed will be changed to 9600 bps
EXAM
P
LE