DIGITAL EAR THERMOMETER
KI-8130
Safety Instruction....................................................1
Device Description and Intended Use.......................2
About Body Temperature..........................................3
Contraindications.....................................................3
Device Overview.......................................................3
Display Overview......................................................4
Quick Start...............................................................4
Explanation of Symbols............................................4
Battery Installation...................................................5
Setting......................................................................5
Memory Function......................................................6
Use...........................................................................7
Cleaning & Disinfection............................................8
Care and Storage.....................................................9
Product Specification ..........................................10
Trouble Shooting.....................................................11
FCC Statement........................................................11
Limited Warranty.....................................................12
Lot Number information..........................................12
Table of Contents
INSTRUCTION MANUAL
Distributed by : 180 INNOVATIONS LAKEWOOD,CO 80215
Manufactured by: K-jump Health Co.,Ltd.
Made in China www.180innovations.com
Question and Answer IconNeed help?

Do you have a question about the 180 INNOVATIONS KI-8130 and is the answer not in the manual?

Summary

Safety Instructions

General Warnings

Key warnings for safe operation and handling of the device.

Precautions

Important cautions to ensure proper functioning and prevent damage.

Device Description and Intended Use

About Body Temperature

Device Overview

Device Components

Identifies key parts of the thermometer like Probe, LCD, Power Button.

Quick Start

Initial Setup Steps

Guides users through installing batteries and preparing for first measurement.

Battery Installation

Setting

Memory Function

Recall Memory

Instructions for recalling stored temperature readings.

Delete All Memory

Procedure to clear all stored temperature data.

Use

Measurement Considerations

Guidance on site preparation and environmental factors before measurement.

Performing a Measurement

Step-by-step instructions on how to take a temperature reading.

Cleaning & Disinfection

Cleaning Process

Detailed steps for cleaning the thermometer probe and body.

Disinfection Process

Methods for disinfecting the device using alcohol solutions.

Care and Storage

Product Specification

Trouble Shooting

FCC Statement

Limited Warranty

Warranty Exclusions

Conditions under which the device warranty is voided.

Lot Number Information

Overview

This document describes the 180° INNOVATIONS DIGITAL EAR THERMOMETER (Model KI-8130), an electronic device designed for measuring human body temperature by absorbing infrared radiation from the ear. It is suitable for use with adult and pediatric patients in a household setting.

Function Description

The thermometer measures body temperature in the ear canal. It provides a digital display of the temperature reading and includes features for memory recall, unit conversion (°C/°F), and self-diagnosis. The device is designed to be user-friendly with a quick start process.

Important Technical Specifications

  • Measuring Site: Ear canal
  • Measuring Times: 3 seconds
  • Measuring Range: 90°F ~ 110°F (32.2°C ~ 43.3°C)
  • Accuracy:
    • 96.8°F ~ 102.2°F (36°C ~ 39°C): ±0.4°F (0.2°C)
    • <96.8°F (36°C): 0.5°F (0.3°C)
    • 102.2°F (39°C): 0.5°F (0.3°C)

  • Resolution: 0.1°F
  • Memory Sets: 9 sets
  • Operating Condition: 60.8°F ~ 104.0°F (16°C ~ 40°C), R.H. of 15% ~ 95% non-condensing
  • Storage Condition: -4°F ~ 120°F (-20°C ~ 50°C), R.H. of 15% ~ 95% non-condensing
  • Battery: AAA battery x 2pcs
  • Battery Life: More than 1000 measurements
  • Auto Shut Off: After 60 seconds of inactivity
  • Dimension: 102.5mm x 26mm x 26mm
  • Weight: 48g (including battery)
  • Warranty: 1 year
  • Guarantee of Quality: ISO 13485, ASTM E1965-98

Usage Features

  • Quick Start: Install batteries, press the power button, wait for two short beeps, place the probe in the ear, press the power button again, and read the temperature.
  • Display Overview: The LCD shows the measured value, unit (°F or °C), ear measurement indicator, measuring indicator, low battery indication, memory indication, and a "wait for next measurement" symbol.
  • Backlight: The display backlight changes color based on temperature:
    • Green Backlight: T ≤ 98.9°F
    • Yellow Backlight: 99°F ≤ T ≤ 99.4°F
    • Red Backlight: 99.5°F ≤ T
  • Battery Installation: Requires 2 new AAA alkaline batteries. Ensure correct polarity. Remove batteries if the device will not be used for a long period.
  • Setting °C or °F Scale: Turn on the device, then press and hold the power button for 2 seconds to toggle between °C and °F.
  • Memory Function:
    • Recall Memory: When the unit is off, press and hold the power button for approximately 3 seconds to view the last memory. Continue pressing to recall up to 9 previous records.
    • Delete All Memory: In memory mode, press and hold the power button to delete all memories. The device will then turn off automatically.
  • Measurement Consideration:
    • Ensure the measuring site is dry and clean.
    • Straighten the ear canal: For children under 12 months, gently pull the ear backward. For children over 12 months and adults, gently pull the ear backward and upward.
    • Place the probe inside the ear canal and press the power button to take a measurement.
    • Wait at least thirty minutes after exercising, bathing, or eating before taking a measurement.
    • If the subject's body temperature is lower than the room temperature, a false reading may occur.
  • Safety Instructions:
    • Read the entire manual before operation.
    • Clean the device before first use and after each measurement.
    • Do not use if malfunctions occur or if it operates abnormally.
    • Children should use under adult supervision.
    • Avoid use near flammable materials, on scarred tissue, open wounds, or abrasions.
    • Allow the device to return to room temperature for at least one hour if stored in extreme temperatures.
    • Do not touch the probe unless taking a measurement.
    • The device is not water resistant; keep dry.
    • Do not drop or expose to heavy shock.
    • Do not bite or swallow the probe or battery cover.
    • Avoid contact with thinners or chemical solvents.
    • Components may be harmful if swallowed; contact a physician if ingested.
    • Do not put the unit in a dishwasher.
    • Performance may degrade if operated or stored outside stated temperature/humidity ranges or if the patient's temperature is below ambient temperature.
    • Use indoors only, away from mobile phones and microwave ovens (minimum 3.3 meters/11 feet for devices exceeding 2W).
    • Readings are for reference; consult a physician if feeling unwell.
    • Do not scrape or scratch the probe.
    • Do not dismantle the device except for battery replacement.
    • Dispose of the device and battery according to local regulations.
    • Not intended for emergency medical services.
    • Calibration is recommended every two years for maximum performance.

Maintenance Features

  • Cleaning & Disinfection:
    • Pre-cleaning: Wash with cold water several times.
    • Cleaning: Clean the probe with a 5-10% mild detergent solution for 10-15 seconds. Continuously clean with cold water to avoid chemical residues. Rinse with drinking or distilled water. Repeat if necessary.
    • Disinfection: Wipe the probe with a cloth dipped in a 70-75% isopropyl alcohol solution for at least 10 minutes.
    • Drying: Air-dry the device at room temperature (68-86°F) for 30-60 minutes.
    • Do not immerse the unit in water or any liquid.
    • Do not use corrosive detergents, thinners, benzene, or other harsh cleaners.
  • Care and Storage:
    • Do not drop or crush the device.
    • Do not dismantle or modify the device other than changing batteries.
    • Avoid storing in extreme environments with direct sunlight, high/low temperatures, high humidity, or severe dust.
    • Contact local agents or distributors if the device does not function properly.

180 INNOVATIONS KI-8130 Specifications

General IconGeneral
Brand180 INNOVATIONS
ModelKI-8130
CategoryThermometer
LanguageEnglish

Related product manuals