Basic Unit Connector Configuration
Legend to the figure
X10,X8 LAN (PoE according to 802.1af) connector
IN1
IN1 terminals for input in passive/ active mode (−30 V to +30 V DC)
OFF = open OR U > 1.5 V
IN
ON = closed contact OR U < 1.5 V
IN
OUT1
OUT1 terminals of active input for or2N Helios IP Security Relay
®
electric lock connection: 8 up to 12 V DC depending on power supply (PoE:
10 V; adapter: power supply voltage minus 2 V), up to 400 mA
RELAY1 RELAY1 terminals with accessible 30 V / 2 A AC/DC NO/NC contact
12V /
2A
External 12 V / 2 A DC supply terminals (3 A for multiple modules)
GND Grounding terminal
RESET RESET / FACTORY RESET button
RGY LED indicators (red/green/yellow)
LINE
OUT
LINE OUT connector (1 V )
RMS
MIC MIC connector for microphone connection
BUS
2N
®
Access Unit bus connector
Device Restart
Press the RESET button shortly to restart the device.