Factory Reset
2N
®
Access Unit is equipped with a RESET button. Press the button shortly (< 1 s) to
restart the system without changing configuration.
Follow the instructions below :to identify the current IP address
Press and hold the RESET button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Release the RESET button.
The device announces the current IP address via the speaker automatically.
Follow the instructions below (DHCP OFF):to switch on the Static IP address mode
Press and hold the RESET button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Wait until the red LED goes off (approx. 5 s).
Release the RESET button.
The following network parameters will be set after restart:
IP address: 192.168.1.100
Network mask: 255.255.255.0
Default gateway: 192.168.1.1
Follow the instructions below (DCHPto switch on the Dynamic IP address mode
ON):
Press the RESET button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Wait until the red LED goes off (approx. 5 s).
Wait until the green LED goes off and the red LED comes on again (another 5 s).
Release the RESET button.