962N TELEKOMUNIKACE a.s., www.2n.cz
®
Follow the instructions below :to reset the factory default values
Press the RESET button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Wait until the red LED goes off (approx. 5 s).
Wait until the green LED goes off and the red LED comes on again (another 5 s).
Wait until the red LED goes off (approx. 5 s).
Release the RESET button.
Available Switches
Location Name Description
Basic
Unit
Relay
1
Passive switch: NO/NC contact, up to 30 V / 1 A AC/DC
Output
1
Active switch output:8 up to 12 V DC depending on power
supply (PoE: 10 V; adapter: power supply voltage minus 2 V), up
to 400 mA