2N TELEKOMUNIKACE a.s., www.2n.cz 58/110
1.
2.
Mounting Completion
Having connected all the wires, make sure that the bushings, if used, are
tightened properly and the RJ-45 connector is inserted in the PCB connector.
Replace the front cover carefully. Make sure that the connector is inserted
correctly and the wires inside the device leave enough space for the board if you
are installing a four-button board. Tighten the four screws thoroughly with the
wrench enclosed (Torx 20) to make the panel fit tightly to the metal chassis.
Caution
Properly installed intercom is waterproof. An incorrect mounting may
compromise the intercom watertightness. Water leakage may damage
the electronic part of the system.
Stainless steel screws are used for the assembly. 2N Helios IP Force
®
Other screws than stainless steel ones corrode soon and may
aesthetically deteriorate the surrounding environment!
Available Switches
Location Name Description
Basic Unit Relay 1 Passive relay switch : NO and NC contacts, up to 30 V / 1 A AC
/DC
Output 1 Active switch output: 9 up to 13 V DC depending on power
supply (PoE: 9 V; adaptor: power supply voltage minus 1 V), max
700 mA
Additional
Switch*
(Part No.
9151010)
Relay 2 Passive relay switch : NO and NC contacts, up to 30 V / 1 A AC
/DC
Output 2 Active switch output 9 up to 13 V DC depending on power :
supply (PoE: 9 V; adaptor: power supply voltage minus 1 V), max
700 mA
Passive relay switch : NO and NC contacts, up to 30 V / 1 A AC
/DC

Other manuals for 2N Helios IP Force