EasyManua.ls Logo

2N Helios IP Force - Page 66

2N Helios IP Force
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2N TELEKOMUNIKACE a.s., www.2n.cz 66/110
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Signalling output
Internal red LED under reader window
WIEGAND interface
Off/Input/Output (as programmed)
Mounting guide:
Switch off the intercom.
Remove the front panel (7) from the intercom.
Mount antenna board (8). Use two enclosed self tapping screws (9).
Plug enclosed cable (11) to the antenna board connector.
Demount a button PCB (1). Don't disconnect its cable!
There will stay four spacers after the switch board removal. Dismount the
bottom right one.
There are two short metal spacers enclosed to the reader. Take a longer one (5),
12 mm long. Screw it into the free hole.
Plug an enclosed plastic support (6) to the reader board from the bottom side.
Put the reader board (4) in the main board connector making sure that the
mounting hole is directly above the spacer.
Screw in a remaining metal spacer (3), 10.5 mm long.
Fit the button PCB (1) back to its position using original bolts (2).
If you want to use the tamper switch (to detect unauthorized opening the case,
as a theft protection), insert the tamper board (10) in the connector located in
the right-hand bottom part of the reader board (4). As the tamper switch shares
the relay output (NO and NC) terminals, you cannot use the RELAY2 output with
the tamper switch at the same time.
Plug the antenna cable (11) to its connector at the reader board (4).
Place front panel back and tighten all four screws.

Other manuals for 2N Helios IP Force