Configuration Rules for Fast Ethernet 77
■ A total network span of 325 m (1066 ft) is allowed in single-repeater 
topologies (one hub stack per wiring closet with a fiber link to the 
collapsed backbone). For example, a 225 m (738 ft) fiber link from a 
repeater to a router or switch, plus a 100 m (328 ft) UTP link from a 
repeater out to the endstations.
Configuration Rules
with Full Duplex
The Switch provides full duplex support for all its ports, including 
Expansion Module ports. Full duplex allows packets to be transmitted and 
received simultaneously and, in effect, doubles the potential throughput 
of a link.
With full duplex, the Ethernet topology rules are the same, but the Fast 
Ethernet rules are:
■ Maximum UTP cable length is 100 m (328 ft) over Category 5 cable.
■ A 2 km (6562 ft) fiber link is allowed for connecting switch-to-switch, 
or endstation-to-switch.