38
Flush Table: HF60
1
High Flow Series
Manifold
# of
Cartridges
Rated Flow Flush Instructions
DP1XX Single Manifold 1
3.5 gpm
(13,25 lpm)
Flush 7.0 gallons (26,5 liters) through
cartridge(s) before use (ush approx. 2 mins.)
DP2XX Twin Manifold 2
7 gpm
(26,5 lpm)
Flush 14.0 gallons (53,0 liters) through
cartridge(s) before use (ush approx. 2 mins.)
DP3XX Triple Manifold 3
10.5 gpm
(39,75 lpm)
Flush 21.0 gallons (79,5 liters) through
cartridge(s) before use (ush approx. 2 mins.)
Flush Table: HF90
1
, HF95-CL
1
, HF95-CLX
High Flow Series
Manifold
# of
Cartridges
Rated Flow Flush Instructions
DP1XX Single Manifold 1
5 gpm
(18,9 lpm)
Flush 10.0 gallons (37,9 liters) through
cartridge(s) before use (ush approx. 2 mins.)
DP2XX Twin Manifold 2
10 gpm
(37,9 lpm)
Flush 20.0 gallons (75,7 liters) through
cartridge(s) before use (ush approx. 2 mins.)
DP3XX Triple Manifold 3
15 gpm
(56,8 lpm)
Flush 30.0 gallons (114 liters) through
cartridge(s) before use (ush approx. 2 mins.)
Flush Table: HF8-S
1,2,3
High Flow Series
Manifold
# of
Cartridges
Flush Instructions
DP1XX Single Manifold 1 Flush approx. 2 mins.
DP2XX Twin Manifold 1 Flush approx. 2 mins.
DP3XX Triple Manifold 1 Flush approx. 2 mins.
System has been tested and certified by NSF International against NSF/ANSI Standard 42, 53 and/
or CSA B483.1 for the reduction of the substances specified on the Performance Data Sheet
COMPONENT
This cartridge is Tested and Certified by NSF International against NSF/ANSI Standard 42 for
materials and structural integrity requirements.
This model is certied by the
Water Quality Association to
WQA/ASPE/ANSI S-803
for Sustainability.
This model is certified by the Water Quality Association to WQA/ASPE/ANSI S-803 for
Sustainability.
1
This model is not certied by WQA to WQA/ASPE/ANSI S-803.
2
NSF COMPONENT listing
3
Flow rate limited by upstream cartridges

Questions and Answers: