EasyManua.ls Logo

4tek MIRAGE - Specialized Maintenance and Safety Checks; Filter and Dryer Maintenance; Mandatory Safety Inspections

4tek MIRAGE
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
This manual is the property of . No part of it may be reproduced in any form.
MIRAGE Line Compressors Instruction Manual
6 - 05
If the unit is fi tted with a HEPA14 lter (Fig. 1), change it in
accordance with the prescriptions of the fi lter User Manual.
For compressors equipped with a dryer, it is essential to service the
dryer:
Once every 2 years turn the drying column upside down.
Replace the drying column 4 years from the date of purchase (Fig. 2)
IMPORTANT
In compliance with the national legislation in your country, carry out the required safety
checks including:
Check the safety valve and replace it if necessary
Use the necessary instruments to check the thickness of the receiver walls
Electrical safety test
2
1