11 Sizing data
Indirect Plate Water Heater Installation & Service Manual
Table 11B Sizing Chart _ 60 - 140
NOTE: Highlighted items are limited by the maximum ow velocity through the piping.
8
APW070DW 80 3 130 168 14
APW120DW 160 2 225 160 15
APW105DW 160 2 225 160 15
8
APW030DW 70 3 75 142 8
220
APW015DW 45 2 75 170
APW050DW 80 3 75
APW090DW 160 2 160 136 9
131
8
APW070DW 80 3 130 159 14
APW120DW 160 2 225 150 15
APW105DW 160 2 225 150 15
8
APW030DW 63 2 75 140 8
210
APW015DW 41 2 75 164
APW050DW 80 3 75
APW090DW 160 2 160 126 9
121
8
APW070DW 80 3 130 149 14
APW120DW 160 2 225 141 15
APW105DW 160 2 225 141 15
8
APW030DW 57 2 75 137 8
200
APW015DW 36.5 2 75 159
APW050DW 74 3 75
APW090DW 144 2 160 125 9
118
8
APW070DW 80 3 130 139 14
APW120DW 160 2 225 131 15
APW105DW 160 2 225 131 15
8
APW030DW 50 1 75 135 8
190
APW015DW 32 1 75 154
APW050DW 66 1 75
APW090DW 128 1 160 123 9
117
8
APW070DW 80 3 130 129 14
APW120DW 160 2 225 121 15
APW105DW 142 2 225 128 15
8
APW030DW 43 2 75 132 8
180
APW015DW 27.5 1 75 149
APW050DW 57.5 2 75
APW090DW 112 1 160 122 9
116
8
APW070DW 75 3 130 122 14
APW120DW 139 2 225 119 15
APW105DW 120 1 225 126 15
8
APW030DW 36.5 1 75 130 8
170
APW015DW 22.5 1 75 145
APW050DW 49 2 75
APW090DW 95 1 160 121 9
116
8
APW070DW 61 2 130 121 14
APW120DW 112 1 225 119 15
APW105DW 97 1 225 124 15
8
APW030DW 29 1 75 128 8
160
APW015DW 18 1 75 140
APW050DW 39.5 1 75
APW090DW 77.5 1 160 120 9
116
8
APW070DW 44.5 2 130 122 14
APW120DW 83 1 225 119 15
APW105DW 70 1 225 124 15
8
APW030DW 21 1 75 127 8
150
APW015DW 12.5 1 75 136
APW050DW 29 1 75
APW090DW 57 1 160 120 9
118
121 8
APW070DW 34 1 130 123 14
APW120DW 64 1 225 121 15
APW105DW 54 1 225 125 15
135 8
APW030DW 15.5 1 75 128 8
60‐140
145
APW015DW 9 1 75
APW050DW 22 1 75
APW090DW 44 1 160 122 9
DOMESTICWATERINLET‐
OUTLET(°F)
BOILERWATERINLETTEMP
(°F)
APWMODEL
DOMESTIC BOILER
FLOW(GPM) PRESSURELOSS(PSI) MAX.FLOW(GPM)
OUTLETTEMP(°F)
MAX.PRESSURELOSS(PSI)

Table of Contents