33
11 Sizing data (continued)
Indirect Plate Water Heater Installation & Service Manual
Table 11C Sizing Chart _ 60 - 160
NOTE: Highlighted items are limited by the maximum ow velocity through the piping.
DOMESTICWATERINLET‐
OUTLET(°F)
BOILERWATERINLETTEMP
(°F)
APWMODEL
DOMESTIC BOILER
FLOW(GPM) PRESSURELOSS(PSI) MAX.FLOW(GPM)
OUTLETTEMP(°F)
MAX.PRESSURELOSS(PSI)
152 8
APW030DW 15 1 75 144 8
60‐160
165
APW015DW 9 1 75
APW050DW 21.5 1 75
APW090DW 42 1 160 138 9
135 8
APW070DW 33 1 130 139 14
APW120DW 62 1 225 137 15
APW105DW 52 1 225 141 15
8
APW030DW 19.5 1 75 143 8
170
APW015DW 12 1 75 154
APW050DW 27.5 1 75
APW090DW 53 1 160 136 9
132 8
APW070DW 42 2 130 137 14
APW120DW 78 1 225 134 15
APW105DW 66 1 225 140 15
8
APW030DW 27 1 75 143 8
180
APW015DW 16.5 1 75 157
APW050DW 36 1 75
APW090DW 71 1 160 134 9
130 8
APW070DW 56 2 130 135 14
APW120DW 104 1 225 132 15
APW105DW 89 1 225 139 15
8
APW030DW 33 1 75 144 8
190
APW015DW 20.5 1 75 162
APW050DW 44 2 75
APW090DW 87 1.5 160 134 9
129 8
APW070DW 68 3 130 136 14
APW120DW 126 1.5 225 132 15
APW105DW 109 1 225 140 15
8
APW030DW 39 1 75 146 8
200
APW015DW 24.5 1 75 166
APW050DW 51.5 2 75
APW090DW 101 1.5 160 135 9
128 8
APW070DW 80 3 130 136 14
APW120DW 147 2 225 132 15
APW105DW 127 1 225 141 15
8
APW030DW 44.5 2 75 148 8
210
APW015DW 28.5 1 75 170
APW050DW 58.5 2 75
APW090DW 115 1.5 160 135 9
129 8
APW070DW 80 3 130 146 14
APW120DW 160 2 225 136 15
APW105DW 145 2 225 143 15
220
APW015DW 32 1 75 175
APW050DW 65.5 2 75
APW090DW 128 1 160 136
129
146 15
8
APW030DW 50 2 75 150 8
9
8
APW070DW 80 3 130 156 14
APW120DW 160 2 225 146 15
APW105DW 160 2 225