A-Star 2018 ED - VERIFYING BRINE DRAW DURING REGENERATION; CHECKING BACKWASH AND RINSE FLOWS; SOFTENER RETURN TO SERVICE; WIRING SCHEMATIC

Default Icon
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
2. After observing fill, press the TOUCH – HOLD button to move the softener into
brining. A slow flow of water to the drain will begin. Verify brine draw from the brine
tank by shining a flashlight into the brine well and observing a noticeable drop in the
liquid level.
NOTE: Be sure a salt bridge is not preventing water with salt contact.
If the softener does not draw brine:
o nozzle and/or venturi dirty or defective.
o nozzle and venturi not seated properly on gasket.
o restricted drain (check drain fitting and hose).
o defective nozzle and venturi seal.
o other inner valve defect (rotor seal, rotor & disc, wave washer, etc.).
NOTE: If water system pressure is low, an elevated drain hose may cause back
pressure, stopping brine draw.
3. Again, press the TOUCH - HOLD button to move the softener into backwash. Look for
a fast flow of water from the drain hose.
A slow flow indicates a plugged top distributor, backwash flow plug, or drain hose.
4. Press TOUCH - HOLD to move the softener into fast rinse. Again look for a fast drain
flow. Allow the softener to rinse for a few minutes to flush out any brine that may
remain in the resin tank from the brining cycle test.
5. To return the softener to service, press TOUCH - HOLD.