switches and solenoid valves. The water connection should be capable of supplying
the volume listed in Table 2 at a pressure of 40 psi.
9.2.6.10 Auxiliary Impeller Flushing
The manual or solenoid valve should be piped up to the water line that
supplies the RotoClone, after the strainer. The connection size is a ½" FPT on the
valve.
9.2.6.11 Water Usage Table
Table 2. Normal Water Supply Rates
1. Decreased or increased water requirements can be provided by changing
nozzle size.
2. For air temperatures in excess of 300F, cooling spray nozzles should be
provided in inlet duct to compensate for evaporation. A safe
approximation will be 0.2 GPM if additional water per 1000 CFM for each
100°F temperature reduction.