10 Dismantling and fitting with removed air inlet and gas outlet / 10.2
Removing the gas outlet casing
© Copyright 2021 ABB. All rights reserved. HZTL4032_EN Rev.Q January 2021
10.2 Removing the gas outlet casing
u Mark the casing position for assembly.
Variant without support
Fig.48: Remove gas outlet casing without support
1. If present: Remove waste gate pipe.
2. Remove insulation ring.
3. Fit swivel lifting eyes (S) to the gas outlet casing (61001). Attach lifting gear to swivel lift-
ing eye and secure to a crane hook.
4. Loosen and remove nuts (51009).
5. Remove the gas outlet casing (61001), set it down properly in an appropriate place and
secure it.
6. Remove and dispose of the gasket(61002).