Parameters 385
62.38 M/F communication
status 2
In the master, displays the status of the communication with
followers specified by parameter 60.20 M/F comm supervision
sel 2.
-
0000h…FFFFh M/F communication status (followers 17…32). 1 = 1
62.41 M/F follower ready
status 1
In the master, displays the ready status of the communication
with followers specified by parameter 60.23 M/F status
supervision sel 1.
-
0000h…FFFFh Follower 1…16 ready status. 1 = 1
62.42 M/F follower ready
status 2
In the master, displays the ready status of the communication
with followers specified by parameter 60.24 M/F status
supervision sel 2.
-
0000h…FFFFh Follower 17…32 ready status. 1 = 1
62.45 Data set 1 data 1
selection
Parameters 62.4562.50 define a target for the data received
in data sets 1 and 3 from the external controller. These data
sets are used in ModuleBus communication with a “standard
drive” (60.50 DDCS controller drive type = ABB standard
drive).
Parameters 62.9562.100 display the data received from the
external controller in integer format, and can be used as
sources by other parameters.
For example, this parameter selects a target for word 1 of data
set 1. Parameter 62.95 Data set 1 data 1 value displays the
received data in integer format, and can also be used as a
source by other parameters.
None
None None. 0
CW 16bit Control Word (16 bits) 1
Ref1 16bit Reference REF1 (16 bits) 2
Ref2 16bit Reference REF2 (16 bits) 3
No. Name/Value Description Def/FbEq16
Bit Name Description
0 Follower 17 1 = Communication with follower 17 OK.
1 Follower 18 1 = Communication with follower 18 OK.
……
15 Follower 32 1 = Communication with follower 32 OK.
Bit Name Description
0 Follower 1 1 = Follower 1 ready.
1 Follower 2 1 = Follower 2 ready.
……
15 Follower 16 1 = Follower 16 ready.
Bit Name Description
0 Follower 17 1 = Follower 17 ready.
1 Follower 18 1 = Follower 18 ready.
……
15 Follower 32 1 = Follower 32 ready.