Page #81 background imageLoading...
Page #81 background image
Operation Manual / TPS44-F.. - TPS61-F..
Troubleshooting 6
Malfunctions during operation 6.3 Page 79
© Copyright 2016 ABB. All rights reserved.
August 2017HZTL2412_ENRevision F
Malfunctions during operation
6.3
Lubricating oil pressure too low
Possible causes Elimination
Engine Oil filter heavily contaminated Clean it
Defective oil pump in lubricat-
ing system
Check / replace it
Manometer display wrong Replace the manometer
Turbocharger Rotor axial clearance too large Contact an ABB Turbocharging
Service Station
Reduction in speed
Possible causes Elimination
Engine Defects of connected cylin-
ders when pulse charging
Contact the enginebuilder
Turbocharger Heavy contamination of the
turbine
Clean it
Damaged rotor components or
bearing
Contact an ABB Turbocharging
Service Station
Pipes Defects such as leaks in the
exhaust gas pipes or charge
air ducts
Make repairs
Increase in speed
Possible causes Elimination
Turbocharger Heavily contaminated nozzle
ring (with 4-stroke application)
Contact an ABB Turbocharging
Service Station
6.3

Table of Contents

Other manuals for ABB HT566981

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HT566981 and is the answer not in the manual?

ABB HT566981 Specifications

General IconGeneral
BrandABB
ModelHT566981
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals