Cleaning the absorption segments
(see Fig.25: Cleaning the filter silencer →48)
u Loosen the tension bands (81270).
u Remove the cover grid (81266).
u Pull out and bend up the sheet-metal coverings (81137), and remove the absorption seg-
ments (81136).
u Clean the absorption segments (81136).
When cleaning, note that the absorption segments (81136) must only be cleaned lightly
with compressed air, a soft brush or a moist cleaning cloth.
u Have any heavily contaminated absorption segments replaced by an ABB Turbocharging
Service Station.
Fitting the filter silencer
(see Fig.25: Cleaning the filter silencer →48)
u Insert the absorption segments (81136) into the sheet-metal coverings (81137).
u Bend the sheet-metal coverings (81137) back to their original shape and insert into the
slotted guides in the filter silencer body (81135).
u Fit the cover grid (81266).
u Fit the tension bands (81270) and tighten them at the locks (81271).
u Any tension bands that have become damaged must be replaced.
u Fit the filter ring (81265), if present.
Page 49 / 171

Table of Contents

Other manuals for ABB HT604877

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HT604877 and is the answer not in the manual?

ABB HT604877 Specifications

General IconGeneral
BrandABB
ModelHT604877
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals