Operation Manual / TPL85-B14/-B15/-B16
Maintenance
5
Cleaning the compressor during
operation
5.4
Page 61
© Copyright 2016 ABB. All rights reserved.
May 2016 HZTL2491_EN Revision B
Wet cleaning using vacuum cleaning device on filter silencer (XC4)
Operating state prerequisites for compressor cleaning with XC4
NOTICE
In order to carry out a successful cleaning procedure which has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
Engine load 25 to 85 %
Start the cleaning cycle according to the following description
Wet
cleaning procedure with XC4.
Procedure for compressor wet cleaning with XC4
01
Cleaning medium vessel 02
Pipe
03
Injection pipe 04
Cleaning instructions
05
Cover
06
Valve
NOTICE
When using the cleaning medium vessel on the filter silencer, refer to
the detailed cleaning instructions on the plate (04) attached to the filter
silencer.
5.4.2

Table of Contents

Related product manuals