26. Ordering for pre-configured IED
Guidelines
Carefully read and follow the set of rules to ensure problem-free order management.
Please refer to the available functions table for included application functions.
PCM600 can be used to make changes and/or additions to the delivered factory configuration of the pre-configured.
To obtain the complete ordering code, please combine code from the tables, as given in the example below.
Example code: REL670 *2.2-A41X00- X00B05-B1X0-AC-CA-B-A6X0-CL1AB1RGN1N1XXXXXXX-KKKXXHKKLAGXSY. Using the code of each position #1-11 specified
as REL670*1-2 2-3-4 4-5 6-7 7-8-9 9 9-10 10 10 10 10 10 10 10-11 11 11 11 11 11 11 11 11 11 11
# 1 - 2 - 3 - 4 - 5 6 - 7 - 8 - 9 -
REL670* 2.2 - X00 - - - - - - -
10 - 11
-
Position
SOFTWARE #1 Notes and rules
Version number
Version no.
2.2
Selection for position #1
Configuration alternatives Ordering no #2 Notes and rules
Single breaker, 1/3 phase tripping, isolated or high impedance earthed systems 1MRK004003-EG A41
Single breaker, 1/3 phase tripping 1MRK004003-FG A42
Multi breaker, 1/3 phase tripping 1MRK004003-GG B42
Single breaker, 1/3 phase tripping, with PMU 1MRK004003-HG D42
ACT configuration
ABB standard configuration X00
Selection for
position #2
Software options Ordering no #3 Notes and rules
No option X00 All fields in the ordering form do
not need to be filled in
High impedance differential protection - 3 blocks 1MRK004001-AB A02 Only for A42/B42/D42
Phase segregated scheme communication 1MRK004001-BE B05
Pole slip protection 1MRK004001-VU B24 Only for A42/B42/D42
Stub protection 1MRK004001-VK B27 Only for B42. One block included
as basic.
Sensitive directional residual overcurrent and power protection 1MRK004001-CT C16 Only for A42/B42/D42
Directional power protection 1MRK004001-VM C39 Only for A42/B42/D42
Overexcitation protection - 2 winding 1MRK004001-DC D03
Frequency protection - line 1MRK004001-ED E04 One block included as basic
General current and voltage protection 1MRK004001-FA F01 Only for A42/B42/D42
Fuse failure supervision based on voltage difference 1MRK004001-HC G03
Autorecloser - 1 circuit breaker 1MRK004001-GD H04 Only for A42/D42. One block
included as basic.
Autorecloser - 2 circuit breakers 1MRK004001-GE H05 Only for B42. Two blocks included
as basic.
Control functionality for up to 10 objects 1MRK004001-GW H37 Only for A41/A42/D42
Control functionality for up to 15 objects 1MRK004001-GY H38 Only for B42
IEC 62439-3 parallel redundancy protocol 1MRK004001-PP P23 Options P23 and P24 require two
SFPs placed in pairs.
IEC 62439-3 High-availability seamless redundancy 1MRK004001-PR P24
IEC 61850-9-2 Process Bus communication, 8 merging units 1MRK004001-PT P30
Synchrophasor report, 8 phasors 1MRK004001-PV P32 Only for A41/A42/B42
Selection for
position #3
1MRK 506 372-BEN -
Line distance protection REL670 2.2
Product version: 2.2
ABB 139