EasyManua.ls Logo

ABB WaterMaster - Introduction; 2.1 Quality Control

ABB WaterMaster
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
WATERMASTER ELECTROMAGNETIC FLOWMETER | DS/WM-EN REV. Y
Specification
WaterMaster specification to OIML R49 Class 1
0.1 (0.44) 1.0 (4.4) 10 (44) 100 (440)
1000 (4402)
Error (%)
Flowrate m
3
/h (GPM)
Typical meter
performance
±0.2 % ±0.9 mm/s
whichever is the greater
Around Q2 the
performance is
±0.7 mm/s
WaterMaster Class 1
specification
OIML R49 Class 1
accuracy limits
DN100 (4 in. NB)
WaterMaster specification to OIML R49 Class 2
0.1 (0.44) 1.0 (4.4) 10 (44) 100 (440) 1000 (4402)
Error (%)
Typical meter
performance
±0.4 % ±0.9 mm/s
whichever is the greater
Around Q2 the
performance is
±0.7 mm/s
WaterMaster Class 2
specification
OIML R49 Class 2
accuracy limits
DN100 (4 in. NB)
Flowrate m
3
/h (GPM)
Although OIML R49 does not define the flow accuracy below Q1, WaterMaster continues to measure flow at lower flow rates
down to a cutoff velocity of ±5 mm/s (±0.2 in./s). The accuracy between cutoff and Q1 is typically ±0.9 mm/s (±0.04. in./s).