S1 Service manual
38
Adjustment
Required test Equipment
1Stability power supply
1The supply voltage can be changed between 3.7V and 68V, and the current
is 3A or more.
2The standard voltage is 4.0V
2DC Ammeter
1 Class 1 ammeter (17ranges and other features).
2 The full scale can be set to either 400mA or 3A.
3 A cable of less internal loss must to be used.
3Frequency counter (F. Counter)
1Frequency of 1GHz or so can be measured
2The sensitive can be changed to 500MHz or blow, and measurements are
highly stable and accurate. (about 0.2ppm)
4Power Meter
1 Measurable frequencyUp to 500MHz
2 Impedance50, instability
3 Measuring rangefull scare of 5W or so
4 A standard cable (5D2W 1m) must be used
5RF Voltmeter (RF V.M)
1Frequency rangeup to 500MHz or so.
6Linear Detector
1 Frequency rangeup to 500MHz or so.
2 Characteristics are flat, CN is 60dB or more.
7Digital Voltmeter
1 Voltage rangeFS=18V or so.
2 Input resistance: 1M or more
8Oscillograph
1 Measuring rangeDC to 30MHZ
2 Provide highly accurate measurements for 5 to 25MHz.
9AF Voltmeter (AF V.M)
1 Measuring range50Hz to 1MHz
2 Maximum sensitivity1mV or more.