EasyManua.ls Logo

Abell S1 - Page 41

Abell S1
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S1 Service manual
41
Test
Equipme
nt
Terminal Part
s
Method
1 Band
pass-filter
1) CHRX center
2)Tra generator output
-40dBm
Connect the spectrum
analyzer to L45 termina
Tra
generator
Spectrum
Analyzer
ANT
L45
TC1
TC2
Adjust the frequency
so that it becomes the
spectrum waveform
shown in fig1.
the adjustment of PMR446
version is the same as
D02
2 Max
Audio
Lever
1)CHRx center
SSG output-47dBm(1mV)
MOD1KHz
DEV±3.0KHz(Wide)
±1.5KHz(Narrow)
test
1.0V
3 Sensiti
vity
1)CHRX center
CHRX LOW
CHRX HIGH
SSG output
-116dBm(0.35µV)
MOD1KHz
DEV±3.0KHz(wide)
±1.5KHz(narrow)
test
SINAD12dB or more
1)CHRX Centre
MONIopen
2) level 5
SSG output-123dBm
level 5 to close the
squelch
Squelch must be off
4. Squelch
Level ( PC
mode)
SSG
Oscillosco
pe
AF.V.M
Distortion
meter
Antenna
Speaker
PC
mode
Transmitter section
Measurement Adjustment
Item
Condition
Test equipment Terminal Parts Method
Specification/
Remark
1Transmit
(PC mode)
1)CHTX center
PTTOn
F. counter VR2 Adjust to center
frequency
Within ±150Hz
Adjust to power
high 1.15W
±0.05W 2. Output
Power
(PC mode)
1)CH: TX centre,
Battery terminal: 4.0V
PTT: ON
Power meter
Ammeter
Antenna
Adjust to power
low 0.55W
±0.05W

Related product manuals