OABLOY*
SETTABLE
FUNCTIONS
OF
EL560,
EL561
ENGLISH
CHANGING
THE
FOREND Fig.
G
1
.Unscrew
the
fixing
screws
and
remove
the
forend.
2,Set
another forend
and
screw
in the
fixing screws. Please note that
a
screw below
the
dead
bolt
is
longer than
the
other screws.
Use
LOCTITE
243 on
each fixing screw.
SETTING
THE
ELECTRICAL
FUNCTION:
FAIL LOCKED FAIL UNLOCKED
Pig.
H
The
lock case
is
delivered
in
Fail locked mode:
Power
off ->
Handle does
not
open
the
lock.
Power
on ->
Handle opens
the
lock.
The
lock case
can be
changed
in
Fail
unlocked
mode. Then
the
lock
works
electrically
in the
following way:
Power
off ->
Handle opens
the
lock.
Power
on ->
Handle does
not
open
the
lock.
The
electrical function
is
changed from
Fail
locked into
Fail
unlocked mode
by
turning
the
changer, which
is
located
on the
case side
of the
lock case,
in the
following way:
1.
Unscrew
the
fixing screw
and
pull
out the
changer.
2.
Turn
the
changer around.
3.
Put the
changer back
and
screw
in the
fixing
screw. Please make sure
that
the
changer
is
straight
and it
fits tightly
in the
lock case.
When
the
arrows
on the
changer
and the
lock case
are
positioned
as
shown
in the
figure,
the
electrical function
is
Fail locked (Fig. H1).
When
the
arrows
on the
changer
and the
lock case
are
positioned
as
shown
in the
figure,
the
electrical function
is
Fail
unlocked (Fig. H2).
SETTING
THE
EXIT HANDLE SIDE
(EL560)
Fig.
I
(Needed tool:
2.5 mm
Allen key)
Exit
side
of the
lock case
is set
with
an
Allen screw.
The
handle,
of
which side
the
Allen screw
is
fixed, always opens
the
lock, while
the
handle
of the
other side
is
controlled electrically.
The
lock case
is
delivered
so,
that
the
Allen screw
is
fixed
on the
case side
of the
lock case.
Exit
handle side
can be
changed
in the
following way:
1.
Remove
the
Alien screw from
the
case side
of the
lock
case
(Fig.
11),
2. Fix the
Allen screw
in the
corresponding hole
on the
other side
of the
lock case
(Fig. I2).
CHANGING
THE
HANDING
OF
THE
TRIGGER BOLT Fig.
J
(Needed
tool:
2 mm
Allen
key)
1.
Press
the
trigger bolt inside
the
lock
case until
the
Allen screw
of the
trigger bolt
is
shown
on the
cover side
of the
lock case.
2.
Unscrew
the
Allen
screw.
3.
Pull
out the
trigger
bolt
and
turn
it
around.
4. Put the
trigger bolt back
in its
place
and
press
it
inside
the
lock case.
5.
Screw
in the
Allen screw.
SETTING
MANIPULATION PROTECTION PLUG Fig.
K
Set the
brass plug
on the
outside
of the
lock case
as
shown
in the
figure.
ATTACHING
THE
CABLE Fig.
L
1.
Connect
the
cable
into
the
connector.
2. Use a
cable
tie to fix the
cable
to the
lock case.
Cut the
cable
tie
short.
SETTING
8/9
SNAP SPINDLE ADAPTERS Fig.
M
8/9
snap
spindle
adapters
are set if the
lock case
is
installed
with
8mm
spindle.
The
adapters
must
be set on the
both sides
of the
lock case.
There
are two
flat sides
and two
sides with
a cup in the
adapter.
The
round markings
on the
handle
follower
of a
lock case denote
the
direction,
in
which
the
adapter
is
set. With EL360
and
EL160
the
direction
of the
adapter
has to be
noticed.
With
EL560/EL561
the
direction
has
no
significance.