Part number 20217, Rev 0
PHARMACY / VACCINE UNDERCOUNTER
REFRIGERATORS AND FREEZERS
PH-ABT-UCFS-0220M, PH-ABT-UCFS-0420W;
PH-ABT-UCFS-0504W
OWNER’S INSTRUCTIONS
This manual describes how to operate and care for your appliance to get the best, most efficient, performance.
READ THIS BOOK!
Note to Customer:
This merchandise was carefully packed and thoroughly inspected before leaving our plant. Responsibility for its
safe delivery was assumed by the carrier upon acceptance of the shipment. As directed on the side of your
packing carton, claims for loss or damage sustained in transit must be made on the carrier as follows:
A.) Visible Loss, Damage, Shortage External Evidence of Loss or Damage: This type of damage must be noted on
the freight bill and acknowledged by the carrier’s agent (driver) at time of delivery. Make sure you get a signed
copy. Send a written request for an inspection to the carrier.
B.) Concealed Damage: This type of damage may not be discovered until the unit is being unpacked. When
concealed damage is discovered, stop unpacking immediately and contact the carrier immediately to report
the claim and request an inspection. This should be done as soon as possible and, in any case, must be done
within 15 days or receiving the merchandise. If at all possible, do not move the item and save all packaging
material for carrier’s inspection.
C.) FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN THE CARRIER REFUSING TO HONOR YOUR
COMPANY’S CLAIM. UNDER NO CIRCUMSTANCES SHOULD THE MERCHANDISE BE RETURNED TO THE
MANUFACTURER. NO RETURNS WILL BE ACCEPTED WITHOUT PRIOR AUTHORIZATION.
Horizon Scientific
125 Varnfield Drive
Summerville, SC 29483
Phone: 800-648-4041
Fax: 843-821-8051
Warranty:
Two-Year Parts and Labor
5 Years Compressor Parts
Revision Date
03/08/2013

Questions and Answers

  • S
    Stephen JacksonAug 3, 2025
    Why does my ABS PH-ABT-UCFS-0220M appliance run too long?
    • P
      Paul AndrewsAug 3, 2025
      Your ABS Laboratory Equipment might run for extended periods due to several reasons. It could be due to frequent door openings, so try to minimize how often you open the door. The control might be set too cold; adjust it to a warmer setting. Also, ensure the room temperature is not too high, as this can also cause the appliance to run longer.
  • M
    Matthew WilkinsAug 7, 2025
    What to do if my ABS PH-ABT-UCFS-0220M Laboratory Equipment unit does not run?
    • B
      Brandon StephensonAug 7, 2025
      If your ABS Laboratory Equipment unit isn't running, there are a few things to check. First, make sure the electrical circuit is 110-120V 60Hz. Ensure the power cord is properly plugged in. Verify that there's power at the electrical outlet and that the breaker hasn't tripped or a fuse blown. Lastly, confirm the unit is not plugged into a Ground Fault Circuit Interrupter (GFCI) outlet.
  • A
    Angie HarveyAug 11, 2025
    Why is there moisture collecting inside my ABS Laboratory Equipment?
    • G
      Gabrielle GomezAug 11, 2025
      Moisture inside your ABS Laboratory Equipment can be caused by a few things. The door gasket might not be sealing correctly, so check it for debris, cracks, or obstructions. The unit's location could be a factor if it's near a doorway or under an air conditioning vent; consider relocating it or redirecting the vent. Too many door openings can also increase moisture. Hot, humid weather can also increase condensation. Finally, ensure there is a water trap (U-shaped loop) in the drain tube near the compressor to prevent air from entering.
  • J
    John HaynesAug 16, 2025
    What to do if my ABS PH-ABT-UCFS-0220M does not maintain the proper temperature?
    • T
      Tiffany RichardsAug 16, 2025
      If your ABS Laboratory Equipment isn't maintaining the correct temperature, consider these factors: the room temperature may be too warm, so place the unit in an air-conditioned room between 65°F and 85°F. Ensure the door is closing properly. Avoid overloading the unit with too many products. Make sure products are not pushed against the rear wall, which can disrupt air circulation; place them evenly on each shelf. If the evaporator is blocked by frost or ice, remove the products, unplug the unit, and allow it to defrost. Also, ensure any thermometer used is placed in the middle of the refrigerator for accurate monitoring.
  • A
    Andres HarrisAug 20, 2025
    Why is there moisture collecting on the outside surface of my ABS PH-ABT-UCFS-0220M Laboratory Equipment?
    • T
      Thomas WilliamsAug 20, 2025
      Moisture on the outside of your ABS Laboratory Equipment is often due to hot, humid weather, which increases condensation. Monitor weather conditions. As humidity decreases, the moisture should disappear, so wait for the humidity to decrease.
  • T
    Tony DawsonAug 25, 2025
    How to eliminate odor inside my ABS Laboratory Equipment?
    • K
      Kevin HaneyAug 25, 2025
      To address odors inside your ABS Laboratory Equipment, ensure the interior is clean. Also, make sure all product containers are tightly sealed to prevent leakage.
  • B
    Brittany GrayAug 29, 2025
    What to do if the door of my ABS PH-ABT-UCFS-0220M Laboratory Equipment will not close?
    • O
      ogriffinAug 29, 2025
      If the door of your ABS Laboratory Equipment won't close, the unit may not be level. Also, check for any dirt, debris, or obstructions preventing a proper seal and clear any obstacles.

Summary

Receiving and Shipping Damage Claims

Installation Procedures

Uncrating and Placement

Instructions for removing the unit from its packaging and positioning it for optimal airflow.

Leveling the Unit

Guide to adjusting the leveling legs for proper unit stability and tilt.

Power Source Requirements

Details on electrical connections, grounding, and circuit protection for safe operation.

Starting and Operation Guide

Initial Unit Startup

Procedure for powering on the unit and allowing it to reach stable operating temperature.

Temperature Control

Information on the thermostat's function and recommended adjustments.

Normal Operation Guidelines

Loading Product

Tips for efficient loading to maintain consistent internal temperatures.

Door Opening Minimization

Advice on reducing door openings to prevent temperature fluctuations.

Quick Troubleshooting Guide

Unit Not Running

Common causes and solutions for a unit that fails to start.

Temperature Maintenance Issues

Troubleshooting steps for units unable to maintain set temperatures.

Appliance Running Too Long

Possible reasons why the unit's compressor runs excessively.

Warm Exterior Walls

Explanation for exterior wall temperature variations.

Compressor Noises

Identifying and addressing unusual sounds from the compressor.

Moisture Issues

Causes and solutions for condensation inside or outside the unit.

Odor and Door Sealing

Addressing interior odors and problems with the door not closing properly.

Maintenance and Cleaning

Interior and Exterior Cleaning

Recommended cleaning agents and methods for unit surfaces and gaskets.

Defrosting Procedures

Steps for safely defrosting freezers when frost accumulates.

Product Warranty Information

Two-Year Limited Warranty

Coverage details for the unit and its parts for the first two years.

Additional Compressor Warranty

Extended warranty coverage for hermetically sealed compressors.

Warranty Limitations and Exclusions

Details on what is not covered, including consequential damages and misuse.

Obtaining Warranty Service

Instructions on how to contact the manufacturer for warranty claims.

ABS PH-ABT-UCFS-0220M Specifications

General IconGeneral
BrandABS
ModelPH-ABT-UCFS-0220M
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals