Installation
47 | EN
Piezo sounder
WBI:
Installer mode > Test > Int. sounders
Alarm panel:
Installer mode > Test > Sounders & signallers -> Int. sounders
Note
It sends a "test tone" to all available indoor sounders (indoor sounder, info module,
control panel, loudspeaker of the hybrid module). All these components are activated
at the same time.
Note
You can set the volume of the different signal tones in the user menu.
User menu -> Configuration -> Volume settings ->
Operator Sounds
Info tones:
Alarm tones:
Housing and wall tamper switches
Check that the switch functions properly.
Exit installer mode on the alarm panel to do this.
Danger
Note that after exiting the installer mode, the alarm panel will execute the
programmed alarm responses to tampering.
Danger
Inform the communication recipient about the test to be carried out to prevent fault
responses, or deactivate communication for this test.
Danger
Make sure that any loud sounds emitted by sounders belonging to this system do not
startle you (e.g. causing you to fall off a ladder) or cause an annoyance.
Open and close the tamper switch.
Check if the correct notifications are shown on the alarm panel and if the corresponding
alarm reactions are triggered.