– 41 –
Radio group: at least two,
maximum 15 RISAs
All networked units of the same
radio group will issue an alarm
when at least one RISA of this group
detects smoke or temperatures


temporarily assigned the “master”
function (of establishing and mana-
ging the radio group)


(e.g. landing or corridor)
Common radio group: is also a normal
radio group
where one or more radio groups

radio group (e.g. stairway), this
becomes a common radio group.
All interlinked alarms of a radio

All alarms of the common radio

a delay period of roughly 60 seconds,
issue alarms if they are linked as
a common radio group to the radio

Alarms are transferred only from the

mon radio group (e.g. stairway)
There is no transfer in the other di-
rection, from the common radio
group (e.g. stairway) to the radio

Up to 14 radio groups can be inter-
linked to a common radio group
A radio group cannot be linked
to a common radio group and
also with other radio groups
Setting Up the “Master”:
Remove the black activation pin
(which also acts as activation protec-
tion); but this will still be needed.
Press red activation button
Inbetriebnahme