T-SERIES CONTROLLER
PROGRAMMING
VARIATION BUFFER
In AUTO mode, a buffer is built in to prevent your fan from turning on and off too
quickly due to small variations in the environment. When the PROBE temperature
exceeds your SETTING temperature, the fan will start running immediately.
However, the PROBE temperature will need to fall below your SETTING
temperature by 4° Fahrenheit or 2° Celsius or more, to stop the fans from running.
In SMART mode, the speed of the fan will decrease by one level for every
4° Fahrenheit or 2° Celsius that the PROBE temperature is below the SETTING
temperature. To change this buffer or increment setting to 2° Fahrenheit or
1° Celsius, hold the MODE button and DOWN button together for three seconds.
To change back to 4° Fahrenheit or 2° Celsius, hold the MODE button and UP
button together for three seconds.
CONTROLLER LOCK
Holding the MODE button for three or more seconds will lock the controller. The
controller will still work as programmed; however, pressing any buttons will not
have an effect and will cause the screen lock icon to flash. This option was
designed to prevent your controller settings from being changed by accident.
Holding the MODE button again for three or more seconds will unlock the
controller.