TABLETOP ICE & WATER DISPENSER
Models AIWD282 AIWD160
SCIWD282 AIWD450
User’s Manual
BEFORE USE, PLEASE READ AND FOLLOW
ALL SAFETY RULES AND OPERATING INSTRUCTIONS
FELIX STORCH, INC.
Summit Appliance Division
An ISO 9001:2015 registered company
770 Garrison Avenue
Bronx, New York 10474
Write Model and Serial Numbers here:
Model No.:
Ser. No.:

Questions and Answers

  • W
    Wendy PerkinsAug 18, 2025
    What to do if Accucold AIWD160 shows a high pressure switch error?
    • T
      Terry MartinAug 19, 2025
      A high pressure switch error can occur due to condenser dust, fan motor failure, or an abnormal cold cycle. Remove any dust, check the fan motor, and inspect for any cold cycle abnormalities. The system should automatically return to normal operation after these actions.
  • J
    jasonhillAug 21, 2025
    Why does my Accucold AIWD160 Dispenser show a water supply error?
    • A
      Andrew FaulknerAug 21, 2025
      A water supply error occurs when the water level sensor doesn't detect water supply for 120 seconds. Check the water supply pressure and inspect the water level sensor. After these checks, the unit should resume operation.
  • M
    Melissa AndersonAug 23, 2025
    How to fix motor restraint in Accucold AIWD160 Dispenser?
    • A
      Aaron GonzalezAug 23, 2025
      Motor restraint can occur if the evaporator inlet/outlet temperature is -18 °C or less for 10 minutes, or due to poor water supply, agitator restraint, or ice jams from scale. Unlock any ice jams, check the water supply line, and inspect for motor restraint faults. After addressing these issues, the unit should resume operation, but will stop after 3 repetitions.
  • K
    Kiara MataAug 26, 2025
    What to do if Accucold AIWD160 displays a temperature sensor error?
    • C
      Crystal CastanedaAug 26, 2025
      A temperature sensor error is displayed when the temperature sensor is either open or shorted. Check the sensor and its attachments for any abnormalities. After repairing the sensor, you can start the operation.
  • A
    Alyssa YoungAug 28, 2025
    Why does my Accucold Dispenser show an evaporator temperature error?
    • J
      Jason McdanielAug 28, 2025
      An evaporator temperature error can occur if the evaporator temperature is 0 °C or more after 30 minutes during ice making, or if the evaporator temperature is over -5 °C after 30 minutes. Check for refrigerant leakage and inspect the sensor and its attachments for abnormalities. After resolving any cooling problems, resupply power to the unit.
  • M
    Michael SandersAug 30, 2025
    What should I do if the Accucold AIWD160's high pressure switch opens multiple times?
    • C
      carpenterkennethAug 30, 2025
      If the high pressure switch opens 3 times or more, contact a service representative. After the necessary actions are taken, the unit can be restarted.
  • C
    Christopher LowerySep 1, 2025
    What to do if Accucold AIWD160 Dispenser shows water level sensor defect?
    • D
      Diane AcostaSep 2, 2025
      A water level sensor defect occurs at the start of ice making if the upper and lower limits are not detected by the water level sensor for 60 seconds. The solution is to replace the water level sensor, after which operation can be restarted.
  • W
    woodsarahSep 4, 2025
    What to do if Accucold AIWD160 Dispenser displays a cover error?
    • M
      Michael AcevedoSep 4, 2025
      A cover error indicates that the outlet cover is open. Close the cover to resolve the issue and resume operation.
  • B
    Bobby JohnsonSep 6, 2025
    What to do if my Accucold Dispenser shows a high pressure switch error?
    • R
      Richard GilbertSep 6, 2025
      A high pressure switch error in your Accucold Dispenser can be caused by condenser dust, fan motor failure, or an abnormal cold cycle. To resolve this: * Remove any dust. * Check the fan motor. * Check for any abnormalities in the cold cycle. If the high pressure switch opens three or more times, contact a service representative.
  • A
    Angie CamposSep 8, 2025
    What to do if Accucold Dispenser shows water supply error?
    • J
      James BuckSep 8, 2025
      If your Accucold Dispenser displays a water supply error, it means the water level sensor isn't detecting water after 120 seconds of attempted supply. Check the water supply pressure and the water level sensor to resolve this issue.