EasyManua.ls Logo

Acer G185H - Page 19

Acer G185H
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Acer
Acer –LCD-G185H&G195H
10. SOP of PCBA ISP Programming
-----Manufacturer of Scaler is Mstar
Manufacturer of FW is SST/PMC
Operational condition:
Equipment: PC, ISP card, signal cable and power cable.
ESD requirements: antistatic wrists, antistatic gloves
(fingers), and connecting cable
Name of ISP program : ISP_Tool_v3.7.5.3
Manufacture of FW IC : PMC/SST/MX
Operational Steps:
Connection: connect PC to PCBA with signal
Cable, and then keep AC and DC in open state