Acer Acer –LCD-G185H&G195H
Test Profile
+25°C/ 50%R.H.(2hrs)-> -30°C/ No R.H.(12hrs).-> +41°C/ 90%
R.H.(12hrs)->+65°C/ 10% R.H.(12 Hrs)->+25°C/ 50% R.H.(2hr)
Max. Wet Bulb Temp 39°C
Altitude 40,000 feet at -30 °C (hold 1 hr)
2.2 Safety, EMC, Ergonomics and Compatibility Requirements
EMC
Safety
EMC&Safety
Ergonomics
2.3 Electrostatic Discharge Requirements
Item Condition Spec
Contact discharge : +4KV
Contact discharge : +8KV
●
Air discharge : +8KV
Electrostatic Discharge IEC61000-4-2(EN55024)
Air discharge : +15KV
●
2.4 Reliability
Items Condition Spec Note
MTBF
Operating condition is 40°C ≧ 60,000 Hours
Excluding the
LCD, CCFL
CCFL Life time Luminance becomes 50%
≧ 50,000 Hours(min)
Note1
Note1. Life time (Hr) is defined as the time when brightness of a lamp unit itself becomes 50%.
3. Electrical and Optical Characteristics and Performance
3.1 Main Power Supply
Items Condition Spec Note
AC Input Voltage Range Universal input full range 100~240VAC /50~60Hz