Confidential 6
No Step Specification Procedure
7 Light Leak The unit can't
accept the
leakage is
brighter than
Gray 10 pattern
- Test Signal : please refer to Test Signal Table
- Test Pattern : 32 Grays, Gray 10_HP, Gray 30_HP
(From Top to Bottom)
- Please check and see if the light leaks.
- Follow up TI DMD Chip Spec.
8 Calibration Calibration
Pattern should
be in full screen
mode
- Once Main Board is changed, firmware upgrade,
Video Calibration & ADC Calibration should be
done as well.
- Video Calibration
- Test Signal : please refer to Test Signal Table
- Test Pattern : Master
- PC Calibration
- Test Signal : please refer to Test Signal Table
- Test Pattern : White (Top) Black (Bottom)
Note:
1. Calibration Pattern should be in Full Screen
Mode.
2. Please refer to 4-6. Guide to Entering Service
Mode and Facotry Reset for entering Service
Mode.
3. Choose and access Video Calibration & PC
Calibration for correction in Service Mode.
Choose "Exit" to leave the Service Mode after all.
9 Contrast /
Brightness
Gray level should
be
distinguishable
and without color
abnormal
- Test Pattern: 64 RGBW scale
10 R, G, B and
White Color
Performance
Each R, G, B
color should be
normal without
color abnormal
issue
- Test Pattern: R, G, B and White Color

Related product manuals