Owner’s Manual &
Installation Manual
ACiQ-09CD-HH-MB, ACiQ-12CD-HH-MB, ACiQ-18CD-HH-MB, ACiQ-24CD-HH-MB
ACiQ Concealed Duct Air Handler
IMPORTANT NOTE:
Read this manual carefully before installing or
operating your new air conditioning unit. Make
sure to save this manual for future reference.

Questions and Answers

  • V
    vwoodwardAug 10, 2025
    Why is my ACIQ Air Handler not working?
    • B
      Brian MccarthyAug 10, 2025
      Your ACIQ Air Handler might not be working due to several reasons: * There could be a power failure; in this case, wait for the power to be restored. * The power might be turned off; ensure the power is turned on. * The fuse might be burned out; replace the fuse. * The remote control batteries might be dead; replace the batteries. * The unit’s 3-minute protection might be activated; wait three minutes after restarting the unit. * The timer might be activated; turn the timer off.
  • A
    Amanda JohnsonAug 26, 2025
    What to do if my ACIQ Air Handler starts and stops frequently?
    • V
      vwilliamsAug 26, 2025
      If your ACIQ Air Handler starts and stops frequently, consider these potential causes: * There might be too much or too little refrigerant in the system; check for leaks and recharge the system with refrigerant. * Incompressible gas or moisture might have entered the system; evacuate and recharge the system with refrigerant. * The system circuit might be blocked; determine which circuit is blocked and replace the malfunctioning piece of equipment. * The compressor might be broken; replace the compressor. * The voltage might be too high or too low; install a manostat to regulate the voltage.
  • M
    melissawongSep 1, 2025
    Why is my ACIQ Air Handler heating poorly?
    • M
      Mia ThompsonSep 1, 2025
      If your ACIQ Air Handler isn't heating well, it could be due to: * Extremely low outdoor temperatures; in this case, use an auxiliary heating device. * Cold air entering through doors and windows; make sure all doors and windows are closed during use. * Low refrigerant due to a leak or long-term use; check for leaks, re-seal if necessary, and top off refrigerant.
  • C
    Craig SanchezNov 16, 2025
    Why is my ACIQ Air Handler cooling poorly?
    • C
      charlesbookerNov 16, 2025
      Poor cooling performance in your ACIQ Air Handler can stem from several causes: * The temperature setting may be higher than the ambient room temperature; lower the temperature setting. * The heat exchanger on the indoor or outdoor unit might be dirty; clean the affected heat exchanger after turning the unit off and removing any obstructions. * Doors and windows might be open; ensure all doors and windows are closed while operating the unit. * Excessive heat might be generated by sunlight; close windows and curtains during periods of high heat or bright sunshine. * Too many heat sources might be in the room (people, computers, electronics, etc.); reduce the amount of heat sources. * Low refrigerant might be due to a leak or long-term use; check for leaks, re-seal if necessary,...

Summary

Safety Precautions

Product Use Warnings

Safety warnings related to using the air conditioner.

Electrical Safety Warnings

Critical warnings regarding electrical safety during installation and use.

Installation Safety Warnings

Crucial safety guidelines for installing the air conditioner unit.

Unit Specifications and Features

Operating Temperature Guidelines

Recommended operating temperature ranges for different modes and unit types.

Care and Maintenance

Troubleshooting

Troubleshooting Safety Precautions

Critical safety warnings before attempting troubleshooting.

Installation Summary

Indoor Unit Installation

Outdoor Unit Installation

Refrigerant Piping Connection

Refrigerant Piping Connection Steps

Detailed instructions for cutting, removing burrs, and flaring refrigerant pipes.

Connecting Refrigerant Pipes

Steps for connecting the copper pipes to the indoor and outdoor units.

Wiring

Electrical Wiring Regulations and Safety

Essential regulations and precautions for performing electrical wiring work.

Outdoor Unit Wiring Procedure

Procedures for preparing and connecting cables for the outdoor unit.

Indoor Unit Wiring Procedure

Procedures for preparing and connecting cables for the indoor unit.

Air Evacuation

Air Evacuation Preparations

Safety and preparation steps before performing air evacuation.

Air Evacuation Procedure

Step-by-step guide for evacuating the refrigerant circuit using a vacuum pump.

Test Run

Pre-Test Run Checks

Checklist of essential points to confirm before performing the test run.

Operational Test Procedure

Detailed procedures for conducting the operational test of the unit.

ACIQ ACiQ-24CD-HH-MB Specifications

General IconGeneral
Voltage208/230V
Phase1
Frequency60 Hz
Airflow800 CFM
Refrigerant TypeR-410A
Cooling Capacity24, 000 BTU
Cabinet TypeHorizontal