i
Blood Glucose Monitoring System
Self monitoring of blood glucose (SMBG) is an integral part of diabetes care,
but the high cost of testing can make this impossible. At ACON, our goal is to
provide high quality glucose monitoring at a price that allows you to test as
often as necessary. Together, we can better manage your diabetes and help
you live a longer and healthier life.
Welcome, and thank you for choosing the On Call
®
Vivid Pal Blood
Glucose Monitoring System. The On Call
®
Vivid Pal Blood Glucose
Monitoring System will give you accurate blood glucose results, from adult and
neonatal capillary whole blood samples, in just a few simple steps.
WARNING:
To ensure accurate results from your On Call
®
Vivid Pal Blood Glucose
Monitoring System, please follow these warning instructions:
Read instructions before use.
Use only On Call
®
Vivid Blood Glucose Test Strips with the On Call
®
Vivid
Pal Blood Glucose Meter.
For in vitro diagnostic use only. Your blood glucose monitoring system is
to be used only outside the body for monitoring the effectiveness of
diabetes control. It should not be used for the diagnosis of diabetes.
For self testing and professional use.
Test only whole blood samples with the On Call
®
Vivid Blood Glucose Test
Strips and On Call
®
Vivid Pal meter.
For self-testers, consult your physician or diabetes healthcare
professional before making any adjustments to your medication, diet or
activity routines.
Keep out of reach of children.
Keep this User’s Manual properly, do not discard it.
By following the instructions outlined in this User's Manual, you will be able to
use your On Call
®
Vivid Pal Blood Glucose Monitoring System to monitor your
blood glucose and better manage your diabetes.

Table of Contents

Questions and Answers:

Acon on call vivid pal Specifications

General IconGeneral
Blood SampleCapillary whole blood
Sample TypeFresh capillary whole blood
Test Time5 seconds
MemoryYes
Battery LifeApproximately 1000 tests
Operating Temperature10 - 40°C (50 - 104°F)
Operating Humidity10 - 90% RH
Hematocrit Range30 - 55%
Measuring Range20-600 mg/dL
Memory Capacity500 test results
Sample Volume0.5 µL
BatteryTwo (2) 1.5V AAA batteries
Storage Conditions-20 - 60°C (-4 - 140°F)

Summary

Getting Started with Your On Call Vivid Pal System

Component Descriptions

Detailed explanation of each component included with the meter and its function.

On Call Vivid Pal Blood Glucose Meter Overview

Diagram and identification of the meter's parts, ports, and buttons for user familiarity.

Understanding the Meter Display

Explanation of symbols, icons, and information shown on the meter's liquid crystal display.

Meter Use and Safety Precautions

Important safety guidelines and crucial usage instructions to ensure accurate and safe operation.

On Call Vivid Blood Glucose Test Strips Guide

How test strips work with the meter and essential instructions for correct application.

Control Solution Usage and Purpose

Information on the control solution and its role in verifying meter and strip accuracy.

Installing the Meter Battery

Step-by-step instructions for correctly installing the CR2032 coin cell battery.

Initial Meter Setup Configuration

Guide to setting the clock, date, time, and other essential meter features before testing.

Performing a Quality Control Test

Procedure to verify the meter and test strips are working correctly before patient testing.

Testing Your Blood Glucose Levels

Step 1: Obtaining a Blood Sample

Detailed guide on preparing and using the lancing device to get a blood sample.

Safe Disposal of Lancets and Precautions

Instructions for safely disposing of used lancets and related precautions.

Step 2: Performing the Glucose Test

Procedure for applying blood to the test strip and interpreting the meter's result.

Interpreting HI and LO Glucose Messages

Understanding and responding to high (HI) and low (LO) blood glucose readings.

Using the Meter's Memory Features

Viewing Stored Blood Glucose Records

How to access and navigate through past blood glucose test results stored in the meter.

Clearing Meter Memory Data

Instructions for safely deleting all previously stored test results from the meter.

Transferring Data to a Computer

Steps required to connect the meter and transfer recorded data to a PC.

Meter Maintenance and Care

Replacing the Meter Battery

Guide on how to replace the meter's battery when it is low or depleted.

Cleaning and Storing Your System

Recommendations for cleaning the meter and lancing device and proper storage.

Suggested Blood Glucose Testing Times and Target Goals

Comparing Meter and Laboratory Results

Troubleshooting Common Meter Errors

Technical Specifications of the Meter

Product Warranty Information

Index of Symbols and Their Meanings

Related product manuals