DOCUMENT NUMBER: OPMM-001E-R0
Proprietary Information: This document is the property of ADVANCED CONTAINMENT SYSTEMS, Inc. It shall not be copied
or duplicated and shall not be submitted to outside parties without the company consent.
Page 2 of 8 8/21/2017
RELEASES:
1. Original Release: January 3, 2005, revision 1
NOTE:
1. The purpose of this document is to provide basic operation and maintenance information for the FORCED
AIR 2000EC PORTABLE HEPA FILTRATION UNIT.
2. This manual is limited to items stated within. Any changes, additions or modifications will require a
document amendment approved by ADVANCED CONTAINMENT SYSTEMS, Inc.
REFERENCE DOCUMENTS:
1. Drawing Num. FA2000EC-ES-R1: Electrical Schematic
2. Drawing Num. FA2000EC-LD-R1: Ladder Diagram
INDEX:
1. GENERAL INFORMATION
2. DIMENSIONS
3. OPERATION
4. FILTRATION
5. FILTER REPLACEMENT
6. ELECTRICAL SCHEMATIC
7. LADDER DIAGRAM
8. REPLACEMENT PARTS LIST
1. GENERAL INFORMATION:
1.1 The FORCED AIR 2000EC PORTABLE HEPA FILTRATION UNIT is designed for indoor use
and to provide the most efficient air filtration with three stages of filtration. The first stage (Pre-
filter Pad) removes large particles up to 10 microns and larger, the second stage (Ring Panel
Filter) removes particles up to 1 micron and larger, and the third stage with HEPA (High
Efficiency Particulate Air) filtration can remove 99.97% of particles 0.3 micron or larger from
the air stream.
NOTE:
ALL UNITS MANUFACTURED BY ADVANCED CONTAINMENT SYSTEMS INC.
(ACSI) MEET ALL STANDARDS REQUIREMENTS SET BY THE AMERICAN
NATIONAL STANDARS INSTITUTE (ANSI) Z2.9, AND ARE OSHA APPROVED.
ELECTRICAL COMPONENTS ARE “UL” LISTED AND “CSA” CERTIFIED.