Questions and Answers

  • A
    Amanda TurnerAug 5, 2025
    Why does my Acson international ADB350B3 Blower compressor operate continuously?
    • P
      Paul DixonAug 5, 2025
      If your Acson international Blower's compressor runs non-stop, it could be due to a dirty air filter. Try cleaning it. Alternatively, the temperature setting might be too low during cooling, so try increasing it. Or, if it's heating, the temperature might be too high, so try lowering it.
  • M
    Michelle CarterAug 9, 2025
    What to do if there is condensation on the front air grille of my Acson international Blower?
    • J
      Joshua DavisAug 9, 2025
      If you find condensation on the front air grille of your Acson international Blower, it's likely due to air humidity or a temperature setting that's too low after the unit has been running for a while. To resolve this, increase the temperature setting and set the unit to operate at a high fan speed.
  • L
    Leon LongAug 13, 2025
    How to resume Acson international ADB350B3 after a power failure?
    • I
      imartinAug 13, 2025
      If your Acson international Blower doesn't restart after a power failure, turn on the unit using the wireless or wired controller.
  • M
    Matthew MartinezAug 18, 2025
    Why is the airflow too slow in my Acson international ADB350B3 Blower?
    • R
      riggsrebeccaAug 18, 2025
      If your Acson international Blower's airflow is too slow, or the room isn't cooling enough, several factors could be at play. The air filter might be dirty, or doors and windows might be open. Also, the air suction and discharge of both indoor and outdoor units may be clogged or blocked. Lastly, the temperature setting might not be low enough.
  • C
    Christopher VargasAug 22, 2025
    Why Acson international Blower compressor does not operate immediately?
    • B
      Bryan ThomasAug 22, 2025
      If your Acson international Blower doesn't start immediately, it might be due to a built-in protection against frequent starting. Please wait 3 to 4 minutes; the compressor should start on its own.
  • A
    Ariana FisherAug 27, 2025
    Why does my Acson international Blower have a bad odor?
    • A
      amberfrostAug 27, 2025
      If your Acson international Blower is emitting a bad odor, it may be due to smoke particles, perfume, or other substances that have stuck to the coil. Contact your nearest dealer.
  • A
    andrew86Aug 31, 2025
    Why is my Acson international ADB350B3 not emitting warm air?
    • D
      derek22Aug 31, 2025
      If your Acson international Blower is not emitting warm air during the heating cycle, it might be in defrost mode. The heating operation will resume once the defrost cycle is complete.

Summary

1. Nomenclature

Model Nomenclature Explanation

Explains the coding system for model names and their components.

3. Product Line Up

ADB Series Product Line Up

Lists available ADB models and their classifications in a detailed table.

3. Application Information

Operating Range

Specifies the allowable temperature range for cooling operation.

Controllers

Electrical Connection and Precautions

Details wiring regulations, safety precautions, and operational checks for controllers.

Sequential Controller Operation

Explains the LCD display and basic operation of the sequential controller.

Error Codes

Fault Codes and Possible Causes

Lists all possible error codes and their corresponding faults.

Installation Precautions

R407 C Refrigerant Handling Guidelines

Provides specific safety measures and handling instructions for R407C refrigerant.

Outdoor Unit Installation

Condensing Unit Location Requirements

Specifies ideal placement for outdoor units to ensure maximum cooling capacity.

Field Piping Arrangements

Maximum Pipe Length and Bends Guidelines

Outlines recommendations for pipe length, elevation, and bends for optimal performance.

Field-charging Guidelines

Scroll Compressor Charging Precautions

Details essential safety points and equipment for field-charging scroll compressor systems.

Shredder Valves and Refrigerant Charge

Shredder Valve Functionality

Explains the function of shredder valves and their role in system access.

Refrigerant Charge Limits and Recommendations

Provides guidelines for proper refrigerant charging and charge limits.

5. Selection Process

Fan Performance Curve Example

Demonstrates using fan curves for model selection and pulley resizing.

Fan Performance Curves

ADB250 D Fan Performance Data

Presents the fan performance curve for the ADB250D model.

Safety Devices Data

Cooling Only (R22) B Series Safety Devices

Lists safety devices and their operating parameters for B Series units.

Cooling Only (R22) D Series Safety Devices

Lists safety devices and their operating parameters for D Series units.

7. Performance Data

Interpolation Method for Performance Calculation

Demonstrates the interpolation method for calculating performance data.

Performance Data Tables

9. Electrical Data

Electrical Data - Cooling Only (R22) B Series

Lists electrical specifications for B Series cooling units.

10. Wiring Diagrams

Cooling Unit Wiring Diagrams

Provides wiring diagrams for cooling units, showing connections between indoor and outdoor units.

Cooling Unit Wiring Diagrams

11. Servicing and Maintenance

General Servicing Guidelines and Cautions

Provides essential guidelines for servicing, cleaning, and general safety precautions.

12. Troubleshooting

Common Faults and Troubleshooting Tips

Lists common issues and provides simple corrective actions for air conditioner malfunctions.

Diagnostic Guidelines

Pressure Reading Analysis for Diagnosis

Offers guidance on diagnosing issues based on refrigerant pressure readings.

Diagnostic Flow Chart

Electric Circuit Diagnosis Flow Chart

Provides a flow chart for troubleshooting electrical circuit issues affecting unit start-up.

Refrigerant Circuit Diagnosis Flow Chart

Offers a flow chart for diagnosing refrigerant circuit and application issues.

13. Exploded View and Parts List

Exploded View and Parts List

Acson international ADB350B3 Specifications

General IconGeneral
ModelADB350B3
Air Flow350 m3/h
Voltage220-240 V
Frequency50 Hz
Noise Level45 dB