Questions and Answers

  • C
    Cassandra MooreAug 5, 2025
    Why does my Acson international AMC100B compressor operate continuously?
    • L
      Lisa JordanAug 5, 2025
      If your Acson international Blower's compressor runs non-stop, it could be due to a dirty air filter. Try cleaning it. Alternatively, the temperature setting might be too low during cooling, so try increasing it. Or, if it's heating, the temperature might be too high, so try lowering it.
  • C
    Cory GutierrezAug 9, 2025
    What to do if there is condensation on the front air grille of my Acson international Blower?
    • S
      Shannon JenkinsAug 9, 2025
      If you find condensation on the front air grille of your Acson international Blower, it's likely due to air humidity or a temperature setting that's too low after the unit has been running for a while. To resolve this, increase the temperature setting and set the unit to operate at a high fan speed.
  • S
    Sarah CunninghamAug 13, 2025
    How to resume Acson international Blower after a power failure?
    • D
      Dale NguyenAug 14, 2025
      If your Acson international Blower doesn't restart after a power failure, turn on the unit using the wireless or wired controller.
  • H
    haydenstaceyAug 18, 2025
    Why is the airflow too slow in my Acson international Blower?
    • C
      carrollmichaelAug 18, 2025
      If your Acson international Blower's airflow is too slow, or the room isn't cooling enough, several factors could be at play. The air filter might be dirty, or doors and windows might be open. Also, the air suction and discharge of both indoor and outdoor units may be clogged or blocked. Lastly, the temperature setting might not be low enough.
  • A
    Ashley ShermanAug 23, 2025
    Why Acson international AMC100B compressor does not operate immediately?
    • S
      sboydAug 23, 2025
      If your Acson international Blower doesn't start immediately, it might be due to a built-in protection against frequent starting. Please wait 3 to 4 minutes; the compressor should start on its own.
  • S
    Sara RamirezAug 27, 2025
    Why does my Acson international AMC100B Blower have a bad odor?
    • B
      Barbara DennisAug 27, 2025
      If your Acson international Blower is emitting a bad odor, it may be due to smoke particles, perfume, or other substances that have stuck to the coil. Contact your nearest dealer.
  • C
    chadedwardsAug 31, 2025
    Why is my Acson international AMC100B not emitting warm air?
    • S
      sandrakennedyAug 31, 2025
      If your Acson international Blower is not emitting warm air during the heating cycle, it might be in defrost mode. The heating operation will resume once the defrost cycle is complete.

Summary

Model Nomenclature

Model Number Components

Explains brand, capacity, series, model type, refrigerant, electrical, and connection codes in the model number.

Product Line Up

Refrigerant Circuit Diagram

Controllers and Operating Guide

Error Codes and Installation

Error Codes and Possible Faults

Lists error codes and their corresponding possible faults for the system.

Installation and Refrigerant Precautions

Field Piping and System Resistance

Field-Charging Guidelines for Scroll Compressors

Precautions and Required Equipment

Details field-charging precautions for scroll compressors and lists the minimal equipment needed.

Refrigerant Charge and Limits

Proper Refrigerant Charge Guidelines

Covers proper refrigerant charge recommendations and charge limits for various compressor models.

Charging Procedures and Recommendations

Controlled Liquid Charging into Suction Side

Details controlled liquid charging into the suction side, emphasizing caution for reciprocating compressors.

5. SELECTION PROCESS

Example 1: Unit Selection Process

Demonstrates unit selection using fan curves, pulley size adjustments, and V-belt length calculations.

Fan Performance Curve

Presents fan performance curves (Total Static Pressure vs. Flowrate) for various models at different RPMs and power inputs.

Safety Devices Data

Safety Devices for B Series (R22)

Lists safety devices like high/low pressure switches, phase sequencers, and their settings for B Series R22.

Safety Devices for D Series (R22)

Lists safety devices like high/low pressure switches, phase sequencers, and their settings for D Series R22.

Safety Devices for D Series (R407 C)

Lists safety devices like high/low pressure switches, phase sequencers, and their settings for D Series R407C.

7. PERFORMANCE DATA

Performance Data Interpolation Method

Explains the interpolation method for calculating performance metrics like TC, SC, and PI at various conditions.

Example Calculation Steps

Demonstrates step-by-step interpolation for calculating Total Capacity, Sensible Heat Capacity, and Power Input.

9. ELECTRICAL DATA

10. WIRING DIAGRAMS

Cooling Unit Wiring Diagrams (ADB vs AMC)

Provides wiring diagrams for various ADB and AMC model combinations, illustrating connections for indoor and outdoor units.

11. SERVICING AND MAINTENANCE

12. TROUBLESHOOTING COMMON ISSUES

Fault Conditions and Corrective Actions

Lists common fault conditions, their probable causes, and recommended corrective actions for troubleshooting.

Diagnostic Guidelines

Provides a systematic approach to diagnosing issues, including pressure reading analysis.

13. EXPLODED VIEW AND PARTS LIST