AWM-G-2009 Electrical Data
Electrical Data - Cooling Only (R410A)
MODEL
INDOOR UNIT A5WM 20G A5WM 25G
OUTDOOR UNIT A5LC 20C A5LC 25C
INDOOR MOTOR
INSULATION GRADE CLASS B CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
RATED INPUT POWER W 47 66
RATED RUNNING CURRENT A 0.22 0.29
MOTOR OUTPUT W 20 25
POLES 44
OUTDOOR MOTOR
INSULATION GRADE CLASS B CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
RATED INPUT POWER W 120 132
RATED RUNNING CURRENT A 0.53 0.58
MOTOR OUTPUT W 64 75
POLES 66
COMPRESSOR
INSULATION GRADE CLASS E CLASS E
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
CAPACITOR mF 45.0 45.0
RATED INPUT POWER W 1485 1717
RATED RUNNING CURRENT A 6.50 7.50
LOCKED ROTOR AMP. A 27 32
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
Electrical Data - Heat Pump (R410A)
MODEL
INDOOR UNIT A5WM 20GR A5WM 25GR
OUTDOOR UNIT A5LC 20CR A5LC 25CR
INDOOR MOTOR
INSULATION GRADE CLASS B CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
RATED INPUT POWER W 47 66
RATED RUNNING CURRENT A 0.22 0.29
MOTOR OUTPUT W 20 25
POLES 44
OUTDOOR MOTOR
INSULATION GRADE CLASS B CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
RATED INPUT POWER W 120 132
RATED RUNNING CURRENT A 0.53 0.58
MOTOR OUTPUT W 64 75
POLES 66
COMPRESSOR
INSULATION GRADE CLASS E CLASS E
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
CAPACITOR mF 45.0 50.0
RATED INPUT POWER (COOLING) W 1463 1662
RATED INPUT POWER (HEATING) W 1379 1672
RATED RUNNING CURRENT (COOLING) A 6.40 7.50
RATED RUNNING CURRENT (HEATING) A 6.10 7.50
LOCKED ROTOR AMP. A 27 26
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.