c) Hot spurt
During cold start, the set temperature of controller is increased by 2°C to stabilize the room temperature
quickly.
After the first stop of compressor or 30 minutes following the start of operation, the temperature setting
will be restored to the original value.
89
(B) COLD BLAST (Cooling cycle)
During cold start, the set temperature of controller is decreased by 20°C to stabilize the room temperature
quickly.
(C) OVERLOAD PREVENTION IN HEATING OPERATION
During heating operation, if the room temperature and outdoor temperature are high, or when the indoor
air filter is choked, the condensing pressure will increase rapidly. To prevent the burn out of compressor,
the M. C. controller will stop the operation of the air conditioner under this condition.
For manual reset type, the ON / OFF button must be pressed to reset the system.