Step Keypad Entry Operation
1 62 Find Door Numbers
2 Press
Each ACTsmart2 beeps their door number
3 Press key or present card To stop the ACTsmart2 Beeping
at each ACTsmart
ACTsmart2 Operating and Installation Manual Rev. 1.3
20
Find Door Number:
Step Keypad Entry Operation
1 61 Find Door Numbers
2 1-8 Enter the door number to be found. The ACTsmart2 assigned the door
number starts to beep.
3 Press a key or present To stop the ACTsmart2 beeping.
a card
Find All Door Numbers:
Adding a Slave to the Network
Another Slave can be added to the network by defaulting it first (see below) and then assigning it a
door number from the Master.
Removing a Slave from the Network
To remove a Slave unit from the network, simply disconnect it from the network.
Replacing a Slave Unit
To replace a Slave Unit, remove the old Slave from the network. Default the new Slave and add it to
the network. Assign a door number to it from the Master.
Replacing the Master Unit
If the Master Unit needs to be replaced, then replace it with a Slave unit already on the system, (as
it will have all the card/PIN information), and make it the Master. Add a new, defaulted Slave to the
network in place of the swapped-out Slave. Then assign a Door numbers to the new Slave - make sure
it is the Door number of the old Slave.
Restoring Factory Defaults
Enter Programming code followed by 80 followed by
. If this is done on the Master ACTsmart2
then all ACTsmart2’s on the network are defaulted (including the Master). If it is done on a Slave
then only the Slave is defaulted.
If the programming code has been forgotten, power up with the tamper open (by removing the main
unit from the mounting plate or the surface mount collar), while holding down the
key. Release the
key and then enter the default Programming Code (9999).
Defaulting memory takes 3-4 seconds. During this time, the buzzer will sound an elongated tone.
ACTsmart2 Mar/Apr 08:ACTsmart2 Mar 08 29/04/2008 17:03 Page 20

Other manuals for ACT ACTsmart2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ACT ACTsmart2 Series and is the answer not in the manual?

ACT ACTsmart2 Series Specifications

General IconGeneral
BrandACT
ModelACTsmart2 Series
CategoryController
LanguageEnglish

Related product manuals