EasyManua.ls Logo

ActronAir ECOFLEX MINI VRF Series User Manual

ActronAir ECOFLEX MINI VRF Series
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ECOFLEX MINI VRF R-32 SERIES
Air Conditioner - Outdoor
Installation and Commissioning Guide
CAUTION:
The system is charged with flammable
refrigerant, safety checks are necessary to
ensure that the risk of ignition is minimised.
IMPORTANT NOTE:
Please read the R-32 Safety Manual and this manual carefully
before installing or operating your air conditioning unit.
Information in this manual is to be used in conjunction with
the R-32 Safety Manual.
Make sure to save this manual for future reference.
Model Numbers
Single Phase Three Phase
MMV-080CS
MMV-100CS
MMV-120CS
MMV-140CS
MMV-160CS
MMV-180CS
MMV-120CT
MMV-140CT
MMV-160CT
MMV-180CT

Table of Contents

Questions and Answers:

ActronAir ECOFLEX MINI VRF Series Specifications

General IconGeneral
RefrigerantR410A
Indoor Unit TypesDucted
Energy Efficiency RatingVaries by model
Control SystemCentralized and individual remote control
Energy Efficiency Ratio (EER)Varies by model
Coefficient of Performance (COP)Varies by model
Operating Temperature Range (Cooling)Varies by model
Operating Temperature Range (Heating)Varies by model
Noise Level (Indoor Unit)Varies by model and unit type
Noise Level (Outdoor Unit)Varies by model
Power Supply220-240V, 50Hz
TypeVRF (Variable Refrigerant Flow)

Summary

PRECAUTIONS

General Precautions

General safety and regulatory compliance guidelines before installation.

PREPARATIONS BEFORE INSTALLATION

Choosing and Preparing the Installation Site

Guidelines for selecting a suitable location and preparing it for installation.

Selecting and Preparing the Refrigerant Piping

Requirements and considerations for selecting and preparing refrigerant piping.

OUTDOOR UNIT INSTALLATION

Refrigerant Piping Connection

Procedures for connecting the refrigerant piping to the outdoor unit.

Airtight Test

Procedure for conducting an airtightness test on the refrigerant system using nitrogen.

Refrigerant Amount to be Added

Guidelines for calculating and adding the correct amount of refrigerant to the system.

ELECTRICAL WIRING

Safety Device Requirements

Specifies safety devices like circuit breakers and wiring requirements for electrical connections.

COMMISSIONING

Checklist Before Test Run

A checklist of essential checks to perform before starting the test run.

Test Run Implementation

Step-by-step guide for performing the test run and initial system setup.

PRECAUTIONS ON REFRIGERANT LEAKAGE

Important Information for the Used Refrigerant

Key information and warnings regarding the use of R-32 refrigerant.

BEFORE OPERATING

Safety Instructions

Detailed safety instructions and warnings for operating the unit.

Related product manuals